Physical Characteristics – MB6
Dimensions
Weight
Power (internal power supply)
Operating Temperature
Non-Operating Temperature
Humidity
Physical Characteristics – MB21B (#F-MB21B-R)
Dimensions
Weight
Power (internal power supply)
Operating Temperature
Non-Operating Temperature
Humidity
HVS-ID-IG-MB6-MB21-20, Issue 01
19-inch rack mountable, 1RU
43.69 mm H x 447.19 mm D x 482.60 mm W
(1.72 inches H x 17.606 inches D x 19.00 inches W)
Empty chassis: 17.5 pounds
Each blade: 0.5 pounds
F-MB6X-RAC: Redundant AC type 90-264VAC 47Hz-63Hz
F-MB6X-MED: ATX Medical Grade, 90-264VAC, 47-63Hz
F-MB6X-DC: DC type 20-36 VDC
300 watt maximum (all types)
0°C to 50°C (32°F to 122°F)
-40°C to 70°C (-40°F to 158°F)
up to 95% non-condensing
19-inch rack mountable, 4RU
178 mm H x 439.98 mm W x 460 mm D
(7.00 inches H x 17.125 inches W x 18.00 inches D)
Empty 21-slot chassis: 38 pounds
Each blade: 0.5 pounds
90-132V and 180-240VAC 47Hz-63Hz
400 watt maximum
0°C to 40°C (32°F to 104°F)
-40°C to 70°C (-40°F to 158°F)
up to 95% non-condensing