MB6 Chassis Removable Fan Tray

The MB6 chassis has a removable fan tray located on the right side (as shown in the figure below). The following
replacement part is available for the fan tray (#F-MB6X-FAN).

MB6 Chassis Indicators and Alarms

The following table summarizes the functions of the fan tray LED indicators along with the alarm behaviors when
faults occur.
Indicator Color & Description
Power LED
Fan LED
OFF
OFF
Solid Green
Solid Green
Solid Green
Solid Red
Solid Green
Solid Red
MB6 and MB21 Multichannel Chassis Installation Guide, v2.0, Issue 01
Figure 6: MB6 Chassis Front View showing Removable Fan Tray
Table 1: MB6 Fan Tray LED Status Indicators and Alarms
Audible
Indication
Alarm
OFF
No power to chassis.
OFF
Power applied to chassis and no issue/fault is reported.
ON
Chassis Power-ON – Fault(s) Detected.
The following faults will trigger the audible alarm and turn the
FAN LED to RED:
One, some, or all fans are blocked,
One, some, or all fans have no power,
An electrical short is detected (V+ to GND) on the fan
tray,
Thermocouple is missing,
Thermocouple is shorted,
Ambient temperature is over 55°C.
OFF
Chassis Power-ON – Fault(s) Detected – Mute button (Alarm
ON/OFF) pushed
To mute the audible alarm, push the Alarm ON/OFF button.
Once the button is pushed, the alarm is muted.
To re-activate the alarm, push the Alarm ON/OFF button a
second time.
MB6 Chassis Removable Fan Tray
Removable Fan Tray
Alarm ON/OFF button
Power LED (green)
Fan LED (red)