3.
Pull the PSU module out of the chassis.
4.
Slide the replacement PSU module in place and then push the injector/ejector handle until the module locks
into the chassis.
5.
Tighten the screws.

Replacing the F-MB6X-RAC and F-MB6X-DC Chassis Power Distribution Unit

The PDU is not hot-swappable, so you must power down the chassis to replace the PDU.
To replace the F-MB6X-RAC or F-MB6X-DC PDU:
1.
Turn off all PDU power switches.
2.
Disconnect all power cords from the chassis.
3.
Using a Phillips #2 head screwdriver, remove the two PDU retaining screws (one on each side of the PDU).
4.
Pull the PDU module out of the chassis.
5.
Slide the replacement PDU module into the chassis and press to click.
6.
Tighten the screws.
7.
Plug all power cords back into the chassis.
8.
Turn on all power switches on the PDU.
MB6 and MB21 Multichannel Chassis Installation Guide, v2.0, Issue 01
F-MB6X-RAC and F-MB6X-DC Chassis Power Components
MB6 (6-Slot) Chassis
15