Installation Requirements; Electrical Requirements; Gas Supply Requirements; Product Dimensions - Dacor Renaissance EG486SCHNG Installation Instructions Manual

Rangetop
Table of Contents

Advertisement

WARNING
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
To prevent an electric shock hazard, the power sup-
ply must meet the specifications stated below.
The electrical and gas supply data on this page is for refer-
ence only. If the requirements below do not agree with the
product data label, use the data on the product data label.

Electrical Requirements

The electrical installation, including minimum supply
wire size and grounding, must be done in accordance
with National Electric Code ANSI/NFPA 70 and local
codes and ordinances. A copy of this standard may be
obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269-9101
The correct voltage, frequency and amperage must be
supplied to the electrical outlet according to the product
data label located on the bottom of the chassis.
The electrical outlet must be installed by a licensed
electrician.
ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required
120 Vac 60 Hz,
15 Amp. (3 wire)

Product Dimensions

A
RANGETOP WIDTH (A)
EG366
EG486

Installation Requirements

Total Connected Load
0.25 Amp @ 120 Vac, 60 Hz
35 7/8" (91.1 cm)
47 7/8" (121.6 cm)

Gas Supply Requirements

Check your local building codes for the proper method
of installation. In the absence of local codes, this
appliance should be installed in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54. The
gas service must be installed by a qualified profes-
sional
Be certain that the rangetop being installed is cor-
rect for the gas service being provided (natural gas or
LP gas). Also, if operating the rangetop at an altitude
above 4000 ft. (1219 m) make sure it is equipped for
high altitude operation. See the inside cover for more
information.
An external manual shut-off valve must be installed
between the gas inlet and the rangetop for the purpose
of turning on or shutting off gas to the appliance.
The factory provided regulator shipped with the appli-
ance must be installed in the gas line that runs from the
gas shut off valve to the rangetop gas inlet. Use only
the regulator provided. The regulator inlet accommo-
dates a 3/4" gas supply line and is also compatible with
a 1/2" house gas supply. The inlet to the rangetop itself
is equipped with a 3/4" male NPT fitting.
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Natural Gas
5" Water Column
Propane (LP)
* Maximum gas supply pressure for all models is 1/2 psi
28" (71.1 cm)
27" (68.6 cm)
26" (66.0 cm)
1 1/2" (3.8 cm) cooking surface
height (grate level) above
countertop
Power cord
32" long
4" (10.2 cm)
3/4" gas inlet, connects to regulator from
bottom or rear of unit, end is recessed
2" (5.1 cm) from chassis bottom
SIDE VIEW
Product tolerances: ±1/16" (±1.6 mm) unless otherwise
noted.
Manifold
Minimum Gas
Pressure
Supply Pressure
6" Water Column
10" Water
11" Water Column
Column
(19.7 cm)
(1.6 cm)
Trim:
7/16"
(1.1 cm)
thick
7 3/4"
5/8"
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Renaissance eg486Renaissance eg366

Table of Contents