SWITCHING BETWEEN SODA (GREEN) & ABRASIVE (RED)
1.
Release Blast Discharge Nozzle shutting off the media fl ow.
2.
Close Soda Valve (Green) and open Abrasive Media (Red) to switch from Soda to Abrasive.
3.
Depress Safety Trigger allowing fl ow although the opposite media will continue to fl ow until the hose has cleared.
GREEN
VALVE
VALVE
fully
open
closed
Full Soda – No Abrasive

MAINTENANCE

1.
Keep your Eastwood Dual Blaster clean, and protect it from damage.
2.
Release pressure from the tank after each use.
3.
When initially pressurizing, check for leaks at the tank top and at all hoses and fi ttings. Leaking joints may be repaired by replacing worn or damaged parts and using
tefl on tape at joints.
4.
Check for worn abrasive hose and fi ttings. The Abrasive Control Valve, manifold, and all parts after the abrasive is ejected from the tank are subject to rapid wear due to
the fl ow of abrasive. Watch especially for leaks, blistering, bulging or thinness of the hose. Replace any parts which appear worn.
10
RED
GREEN
VALVE
fully
partially
open
RED
VALVE
partially
open
Infi nite Mix Between
Soda/Abrasive
Eastwood Technical Assistance: 800.544.5118 >> techelp@eastwood.com
GREEN
VALVE
VALVE
fully
closed
open
Full Abrasive – No Soda