Advanced Info - CanadianSolar CSI-25K-T400 Series Installation And Operation Manual

Grid-tied pv inverter
Table of Contents

Advertisement

7. Operation
7.4 Advanced Info - Technicians Only
NOTE:
To access to this area is for fully qualified and accredited technicians only.
Enter menu "Advanced Info." and "Advanced settings" (need password).
Select "Advanced Info." from the Main Menu. The screen will require the password as below:
YES=<ENT> NO=<ESC>
Password:0000
Figure 7.5 Enter password
After entering the correct password the Main Menu will display a screen and you will be able to
access to the following information.
1. Alarm Message 2. Running message 3. Version 4. Daily Energy 5. Monthly Energy
6. Yearly Energy 7. Daily Records 8. Communication Data 9. Warning Message
The screen can be scrolled manually by pressing the UP/DOWN keys. Pressing the ENTER
key gives access to a submenu. Press the ESC key to return to the Main Menu.
7.4.1 Alarm Message
The display shows the
100
latest alarm messages (see Figure 7.6). Screens can be scrolled
manually by pressing the UP/ DOWN keys. Press the ESC key to return to the previous menu.
Alm000: OV-G-V
T: 00-00 00:00 D:0000
Figure 7.6 Alarm Message
7.4.2 Running Message
This function is for maintaince person to get running message such as internal temperature,
Standard No.1,2,etc.
Screens can be scrolled manually by pressing the UP/DOWN keys.
7.4.3 Version
The screen shows the model version of the inverter. And the screen will show the
software version by pressing the UP and DOWN at the same time.(see Figure 7.7).
.28.
Software Version: D20001
Figure 7.7 Model Version and Software Version
7.4.4 Daily Energy
The function is for checking the energy generation for selected day.
YES=<ENT> NO=<ESC>
Select:
Figure 7.8 Select date for daily energy
Press DOWN key to move the cursor to day, month and year, press UP key to change the digit.
Press Enter after the date is fixed.
2019-01-01: 051.3kWh
2019-01-01: 061.5kWh
Figure 7.9 Daily energy
Press UP/DOWN key to move one date from another.
7.4.5 Monthly Energy
The function is for checking the energy generation for selected month.
YES=<ENT> NO=<ESC>
Select:
Figure 7.10 Select month for monthly energy
Press DOWN key to move the cursor to day and month, press UP key to change the digit.
Press Enter after the date is fixed.
2019-01: 0510kWh
2019-02: 0610kWh
Figure 7.11 Month energy
Press UP/DOWN key to move one date from another.
7. Operation
Model: 08
2019-01-01
2019-01
.29.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents