Htmpinf - Canon WUX500ST User Commands

Hide thumbs Also See for WUX500ST:
Table of Contents

Advertisement

HTMPINF

High temperature caution display
Format
Setting
Command
Response
Reference
Command
Response
<High temperature caution display setting parameter:ID>
Parameter
ON
OFF
Environment
Power mode restriction
LAN
SL0 SL1 SL3 PM ON SL0 SL1 SL3 PM ON ST PM ON D-RGB A-RGB COMP HDMI HDBT LAN USB
No No No No Yes No No No No Yes No No Yes
Example
(Setting)
>HTMPINF=ON
< i:OK
(Reference)
>GET=HTMPINF
< g:HTMPINF=ON
Note: '>' indicates a command; '<' indicates a response.
HTMPINF=<High temperature caution display setting parameter:ID>
i:OK
GET= HTMPINF
g:HTMPINF=<High temperature caution display setting parameter:ID>
Note: See "Error list" for any response other than the above.
Meaning
Turned on
Turned off
WiFi
RS-232C
Yes
-54-