Iskra ME382 (& MT382) Smart Meter – Installer Instructions
Although installing this smart meter only involves connecting four wires, we recommend that it should only
be carried by a qualified electrician. However, the direct replacement of an existing meter, outside of a
special area
, does not currently need notification to Building Control by a Competent Person under Part P.
The users may occasionally need to push the blue button and see the LCD screen – so if possible position
eye level or below
the meter at
in an accessible place.
make a note of any credit on the meters that you are replacing
If required, please
so
that it can be transferred to the new meter.
The supply circuit must be disconnected during the installation, and only re-energised once all the wiring
connections are secure and the terminal cover is installed. Please also check that there is electricity in the
flat downstream of the meter after the installation.
These meters are remotely read and credited by the tenant and if they were to be installed on the wrong
it is really important that the
circuit then that tenant would be crediting his neighbour's meter. So
correct meter is installed in the correct location.
The meters are dispatched with the
location printed on the packaging box, and there is also a meter serial number which can be used to match
the correct location by the labels. (If the wrong meter has accidentally been installed in the wrong location
please tell us so that we can correct it remotely).
Certain zones within a room containing a bath or shower, or a room containing a swimming pool or sauna heater.
version 3.4 4 July 2017

Advertisement

loading

Summary of Contents for Iskra ME382

  • Page 1 Iskra ME382 (& MT382) Smart Meter – Installer Instructions Although installing this smart meter only involves connecting four wires, we recommend that it should only be carried by a qualified electrician. However, the direct replacement of an existing meter, outside of a ...
  • Page 2 To install the ME382 – single phase meter simply connect the four cables: live input and output, and neutral input and output. The MT382 is a three phase meter with eight cables: i.e. live input and outputs for each of the three phase.
  • Page 3 Wiring Diagrams for ME382 – British Standard Note M is for Mains and L is Load (ie the Output) So looking at the meter from the front is Left: Mains Live | Mains Neutral | Load Neutral | Load Live...

This manual is also suitable for:

Mt382