Initialization (Reset)/Functional Restriction Setting (Function) - Sharp PN-L702B Operation Manual

Tft color lcd monitor
Hide thumbs Also See for PN-L702B:
Table of Contents

Advertisement

Initialization (Reset)/Functional Restriction Setting (FUNCTION)

You can return the settings to their factory-preset values and
restrict operations.
SIZE
1. Hold
down until "F" appears in the upper left
corner of the screen.
2. While "F" appears, press
order.
FUNCTION
ALL RESET
ADJUSTMENT LOCK
ADJUSTMENT LOCK TARGET
RS-232C
OSD DISPLAY
LED
TEMPERATUREALERT
STATUSALERT
POWER BUTTON
CONTROLLER INPUT
3. Select and set the items.
ALL RESET
Resets the settings to the factory default settings.
Press
, select ALL RESET, and then press
After initialization, turn the main power switch off and
then back on.
When the PN-ZB01 (optional) is attached, press
select the resetting method, and then press
ALL RESET1 ....Resets all the settings to the factory
default settings.
ALL RESET2 ....Returns all settings to the factory default
settings except for the following items:
LAN SETUP, RS-232C/LAN SELECT,
ID No. SET, BAUD RATE, NETWORK,
MAIL, SERVICE & SUPPORT, and
SNMP (See page 26, and pages 47 to
50.)
ADJUSTMENT LOCK
You can disable operations on the monitor and the
remote control unit that use buttons.
OFF ...Enables operation.
ON 1 ..Disables all operations other than turning power
on/off and FUNCTION.
ON 2 ..Only the FUNCTION operation is enabled.
Disables all operations other than FUNCTION (not
even power on/off).
ADJUSTMENT LOCK TARGET
Sets the target to prohibit operation of with
ADJUSTMENT LOCK.
REMOTE CONTROL ..... Prohibits remote control
MONITOR BUTTONS ... Prohibits monitor button
BOTH ............................. Prohibits remote control and
RS-232C
(RS-232C/LAN when the PN-ZB01 (optional) is
attached)
Specifies whether to allow control via RS-232C or LAN
(see pages 32 and 43).
,
,
,
in that
1/1
OFF
UNLOCKED
ON1
ON
LED
OFF
MONITOR
END...[MENU]
MENU
.
MENU
.
operation
operation
monitor button operation
OSD DISPLAY
Shows/hides the menu, modes, and messages.
The FUNCTION screen cannot be hidden.
ON 1 .............. Shows all menus, modes, and messages.
ON 2 .............. Hides messages automatically displayed
OFF ............... Hides all menus, modes, and messages.
LED
Specifies whether to light the power LED.
OFF cannot be selected when STANDBY MODE is LOW
POWER.
TEMPERATURE ALERT
Selects the notification method for an abnormal
temperature.
OFF .............. Do not notify about an abnormal
OSD & LED .. When an abnormal temperature is
LED............... When an abnormal temperature is
STATUS ALERT
Selects the notification method for a hardware error.
,
OFF .............. Do not notify about the error.
OSD & LED .. When a hardware error is detected, the
LED............... When a hardware error is detected, the
POWER BUTTON
Normally, leave this setting as MONITOR.
When using an optional part, if instruction appears,
change the setting accordingly.
CONTROLLER INPUT
Normally, you do not need to change this setting.
When using an optional part, if instruction appears,
change the setting accordingly.
MENU
4. Press
to return to the normal screen.
TIPS
• When both abnormal temperature and hardware error are
detected, the hardware error notification overrides.
• If TEMPERATURE ALERT or STATUS ALERT is set to
OSD&LED, alert messages will appear even if the OSD
DISPLAY is set to ON 2 or OFF.
by the display. Shows messages during
operation.
temperature.
detected, the power LED flashes in red
and green alternately and the screen
displays a message: TEMPERATURE.
detected, the power LED flashes in red
and green alternately.
power LED flashes in red and the screen
displays a message: STATUS [xxxx].
power LED flashes in red.