Serveraid Ispr, Bcs, And Ecs Post Error Codes - IBM Netfinity ServeRAID-4L Ultra160 User Reference

Scsi controller
Table of Contents

Advertisement

ServeRAID ISPR, BCS, and ECS POST error codes

Notes:
1. When the ServeRAID controller requires your input, a list of function keys will
2. Where the Action information tells you to start the IBM ServeRAID configuration
3. Where sid or ch appears in these messages, sid is the SCSI ID for the device,
4. Where m or n appears in these messages, a number will appear in the actual
ISPR (Interrupt Status Port Register) codes
Basic and Extended Configuration Status Register Codes
BCS
ECS
Explanation and possible recovery action
Code
Code
Explanation:The ServeRAID controller is not functioning properly.
not in
not in
Action:Have the server serviced.
table
table
00
01
Explanation:Invalid flash configuration.
Action:Start the IBM ServeRAID Support CD and follow the instructions that appear on the
screen.
If no instructions appear or if the problem persists, have the server serviced.
appear below the message.
program, insert the IBM ServeRAID Support CD into the CD-ROM drive; then,
restart the server. The Action column also provides general information about
the message.
and ch is the channel to which the device is attached.
message.
Code
Explanation
1xxx to
The POST detected an internal error.
7xxx
2601 to
The POST detected an error with the
260B
ServeRAID subsystem.
2610
The POST detected an error with the
ServeRAID controller hardware.
2620
The POST detected that a ServeRAID
configuration or hard disk error
occurred.
8xxx to
The POST detected an error with the
Bxxx
SCSI interface.
Action
Have the server serviced.
Have the server serviced.
Have the server serviced.
Start the IBM ServeRAID Support CD
and view the existing device and
configuration information for your
ServeRAID subsystem. If you cannot
locate and correct the configuration
problem or the failing device, or if the
problem persists, have the server
serviced.
Verify that the SCSI cables are correctly
connected and the SCSI termination is
set properly for each installed SCSI
device.
If you cannot locate and correct the
SCSI problem, or if the problem
persists, have the server serviced.
Chapter 9. Solving ServeRAID problems
63

Advertisement

Table of Contents
loading

Table of Contents