Explanation and possible recovery action
07
2C
Explanation:Online/Rebuild and Ready/Standby drives are not responding, and a drive was
found at the incorrect SCSI ID.
Action:Press F4, F5, F6, or F10.
07
38
Explanation:Online/Rebuild, Ready/Standby, and Hot-Spare/Standby Hot-Spare drives are not
responding.
Action:Press F4, F5, or F10.
07
3C
Explanation:Online/Rebuild, Ready/Standby, and Hot-Spare/Standby Hot-Spare drives are not
responding, and a drive was found at the incorrect SCSI ID.
Action:Press F4, F5, F6, or F10.
07
48
Explanation:Online/Rebuild drives are not responding, and unidentified drives were found.
Action:Press F4, F5, or F10.
07
4C
Explanation:Online/Rebuild drives are not responding, and a drive was found at the incorrect
SCSI ID, and unidentified drives were found.
Action:Press F4, F5, F6, or F10.
07
58
Explanation:Online/Rebuild and Hot Spare/Standby Hot-Spare drives are not responding, and
unidentified drives were found.
Action:Press F4, F5, or F10.
07
5C
Explanation:Online/Rebuild and Hot Spare/Standby Hot-Spare drives are not responding, a
drive was found at the incorrect SCSI ID, and unidentified drives were found.
Action:Press F4, F5, F6, or F10.
07
68
Explanation:Online/Rebuild and Ready/Standby drives are not responding, and unidentified
drives were found.
Action:Press F4, F5, or F10.
07
6C
Explanation:Online/Rebuild and Ready/Standby drives are not responding, a drive was found at
the incorrect SCSI ID, and unidentified drives were found.
Action:Press F4, F5, F6, or F10.
07
78
Explanation:Online/Rebuild, Ready/Standby, and Hot-Spare/Standby Hot-Spare drives are not
responding, and unidentified drives were found.
Action:Press F4, F5, or F10.
07
7C
Explanation:Online/Rebuild, Ready/Standby, and Hot-Spare/Standby Hot-Spare drives are not
responding, a drive was found at the incorrect SCSI ID, and unidentified drives were found.
Action:Press F4, F5, F6, or F10.
09
00
Explanation:No error occurred.
Action:No action is required.
09
10
Explanation:Hot-Spare/Standby Hot-Spare drives are not responding.
Action:Press F4, F5, or F10.
09
20
Explanation:Ready/Standby drives are not responding.
Action:Press F4, F5, or F10.
09
30
Explanation:Hot-Spare/Standby Hot-Spare and Ready/Standby drives are not responding.
Action:Press F4, F5, or F10.
®
®