Section 7: Field Setup Using Local Controls
May 2019
7.2

Setup Mode Display Sequence

The three (3) amber LED's for the LOR section flash to indicate Setup Mode. When in setup
mode, the user must enter the REMOTE(NEXT) or LOCAL(BACK) within 120 seconds or the
display will revert back to the normal display mode.
Setup data may be changed by using the UP & Down entries of the Control Knob.
The UP and Down entries are active only after a valid pass-code is entered and the Selector
Switch is in the STOP position. The default pass-code is P1 00 and P2 00. Once the correct
passcode is entered and accepted at the actuator controls, the user will then be able to
advance thru the displays shown in the Main Menu table on the following page.
The table on the following page (see Table 6) shows the sequence of the setup menus.
It also shows the selections, units, and defaults. Each time the REMOTE(NEXT) selector
knob is selected, the display advances to the next menu item. Each time the LOCAL(BACK)
selector knob is selected, the display backs up to the previous menu item. The UP and
DOWN control knob is used to increment or decrement the value shown in the table.
Following is an example for changing the Torque Limit. In this example the current torque
value is the default value of 60%.
1)
2)
3)
4)
5)
6)
NOTE:
Use Selector Knob to select Menu and Use Control Knob to select Units.
22
Enter setup mode – Selector knob Off – Rock control knob back and forth until
3 selector LEDs begin to flash and Fd is displayed. When using the selector knob
to advance to the next menu or back to the previous menu, always return the
selector to the Off position to complete the cycle.
Use control knob to change the value of AH to 0 – Rotate selector knob clockwise
to Remote (Next) to display P1 (1st passcode). The display will alternate between
P1 and the value (default is 00). If the passcode has been changed, rotate the
control knob clockwise to advance the display to the correct 1st passcode. Rotate
the selector knob clockwise to advance to the next display, P2. The display will
alternate between P2 and value of the 2nd passcode (default is 00). If the passcode
has been changed, rotate the control knob clockwise to increment the display to
the correct 2nd passcode.
Repeatedly cycle the selector knob clockwise to advance to the next menu item
until C2 is displayed. This is the torque limit setting as shown in the following table.
The display will alternate between C2 and the value of C2 which we have assumed
to be 60.
Rotate the control knob clockwise to the "up" position to increase the torque limit
setting. Rotate the control knob counterclockwise to the "dn" position to decrease
the torque limit setting.
Repeatedly cycle the selector knob to the Remote (Next) position and the Off
position to advance though the remaining menu items until the EP (Exit Program)
is displayed.
If it is desirable to exit, use the control knob "up" to display a 1 value. Use the
selector knob Remote (Next) to select exit. The system and display will return to
normal operating mode.