Whirlpool  UXT4230AYB Installation Instructions And Use And Care Manual page 10

30" (76.2 cm) and 36" (91.4 cm) range hood
Table of Contents

Advertisement

Available languages

Available languages

NOTE: The 7" (17.8 cm) round vent mounting plate and
3 " x 10" (8.3 x 25.4 cm) rectangular vent damper can be
installed up to 1" (2.5 cm) on either side of the hood
center to accommodate off center ductwork.
A
D
B
A. Vertical damper
B. 3.5 x 9.5 mm screws
If a vent damper is installed with a wall cap with damper,
check that they do not interfere with each other. Remove
the vent connector damper flap if they interfere.
Non-vented (recirculating) installations - No vent
attachments. Removal of the recirculation cover plate is
required. Remove the two screws from the recirculation
cover plate and remove.
A. Recirculation cover plate
B. Screws
Damper Flap Removal for 3¼" x 10" (8.3 x 25.4 cm) Vent
Connector
1. Bend retainer wire out of damper flap catch tab.
B
A
H
G
F
A. Retainer wire
B. Damper flap wire guide
C. Plastic end caps
D. Stop tabs
10
B
C
C. Vent knockouts
D. Horizontal damper
A
B
C
E
E. Vent connector housing
F. Foam
G. Damper flap catch tab
H. Damper flap
2. Slide retainer wire to the side to allow one end of retainer wire
to come out of the damper flap wire guide and plastic end
cap.
3. Lift end of retainer wire and slide it out of the other damper
flap wire guide and plastic end cap to remove.
4. Push the small end of the plastic end caps out of vent
connector housing.
5. Lift the damper flap out of the vent connector housing.
6. Remove the foam from the stop tab.
7. Bend the stop tabs so they are flush with the damper side
walls.
8. Discard the retainer wire, plastic end caps, damper flap and
the foam.
Power Supply Cable Installation
1. For direct wire installations, run the home power supply cable
according to the National Electric Code or CSA standards
and local codes and ordinances. There must be enough
wiring from the fused disconnect (or circuit breaker) box to
make the connection in the hood electrical terminal box.
For optional power supply cord kit installations, follow the
instructions in the "Make Electrical Connection" section.
NOTE: Do not reconnect power until the installation is
complete.
2. Remove the screw from the terminal box cover. Remove
terminal box cover and set aside.
3. Remove the power supply knockout from the top or rear of
the vent hood (depending on the incoming location of your
home power supply cable), and install a UL listed or CSA
approved
" strain relief.
A
A. Power supply knockout
4. Using 2 or more people, lift the hood into final position. Feed
enough electrical wire through the ½" UL listed or CSA
approved strain relief to make connections in the terminal
D
box. Tighten the strain relief screws.
5. Position the range hood so that the large end of the keyhole
slots are over the mounting screws. Then push the hood
toward the wall so that the screws are in the neck of the slots.
Tighten the mounting screws, making sure the screws are in
the narrow neck of slots.
6. Connect ventwork to hood. Seal joints with vent clamps or
duct tape to make secure and airtight.
7. Check that back draft dampers work properly.
A
B
A. Terminal box cover
B. Screw

Advertisement

Table of Contents
loading

Table of Contents