Comfort Dip Switch Setting Pattern(Various Combination Setting)
<Dip Switch>
(The illustrated switch settings show the factory settings for the Propane and 60°C preset.)
• Switching gas type
Dip SW setting for gas type
No. 1
OFF
ON
• Changing hot water temperature (when the remote controller is not connected, the hot
water temperature setting can be changed by selecting one of these settings.)
Dip SW settings for different temperature
No. 2
OFF
OFF
OFF
* Setting change after the power is turned on is ineffective.
* T he system recognizes the settings and makes them effective before power is turned
on.
* When the remote controller is connected, the Dip SW settings become ineffective.
* I nstructions for delivery temperature adjustment for 50°C preset model are located in
the pocket inside the appliance front cover.
To switch gas type (Propane or Natural Gas)
To change hot water temperature (without remote controller)
To fix to the minimum combustion
To fix to the maximum combustion
Applicable gas type
Propane
Natural Gas
No. 3
No. 4
ON
OFF
OFF
OFF
OFF
ON
Temperature (°C)
48
60
70
- 35 -