Download Print this page
Thermann 25THMS124P Installer Manual

Thermann 25THMS124P Installer Manual

25l and 50l electric storage water heaters
Hide thumbs Also See for 25THMS124P:

Advertisement

INSTALLER'S
MANUAL
25L and 50L
Electric Storage Water Heaters
Models
25THMS124P | 25THMS136
50THMS124P | 50THMS136

Advertisement

loading
Need help?

Need help?

Do you have a question about the 25THMS124P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Thermann 25THMS124P

  • Page 1 INSTALLER’S MANUAL 25L and 50L Electric Storage Water Heaters Models 25THMS124P | 25THMS136 50THMS124P | 50THMS136...
  • Page 2 Thermann Installer’s Manual 25L & 50L Electric Storage Water Heaters Specifications and materials may change without notice. Effective for all Thermann 25L & 50L Electric Storage Water Heaters manufactured and sold after 1st July 2016.
  • Page 3: Table Of Contents

    CONTENTS Installation Requirements Technical Data Plumbing Connections Filling and Draining Electrical Connection Handover to the Customer...
  • Page 4: Installation Requirements

    Thermann Installer’s Manual 25L & 50L Electric Storage Water Heaters INSTALLATION REQUIREMENTS General: Location: This water heater must be installed The water heater should be located as by a licensed tradesperson, and in close as possible to the most frequently accordance with: used hot water outlet.
  • Page 5: Technical Data

    TECHNICAL DATA Nominal Dimensions Specifications Total Height (A) Storage Capacity (L) Total Width (B) Hot Water Delivery (L) Outlet Height (C) Net Weight Empty (kg) Inlet Height (D) Element Sizes (kW) 2.4, 3.6 2.4, 3.6 Electrical Entry (E) Relief Valve: Pressure (kPa) 1000 Temperature (°C)
  • Page 6: Plumbing Connections

    Thermann Installer’s Manual 25L & 50L Electric Storage Water Heaters PLUMBING CONNECTIONS Relief Valve: The PTR Valve is not intended to enable connection of the water heater to The Pressure & Temperature Relief (PTR) supplementary energy sources such as Valve, along with a brass reducer, is solar panels or slow combustion stoves.
  • Page 7 PLUMBING CONNECTIONS Water Supply: Cold Water Connection: This water heater has been manufactured The water heater is intended to be to suit the water conditions of most permanently connected to the water Australian metropolitan supplies. supply main, and not connected by a hose-set.
  • Page 8: Filling And Draining

    Thermann Installer’s Manual 25L & 50L Electric Storage Water Heaters FILLING AND DRAINING Filling the Water Heater: Draining the Water Heater: The water heater must be filled with 1. Turn off the electricity supply to the water before turning on the electrical water heater.
  • Page 9: Electrical Connection

    ELECTRICAL CONNECTION General: The electrical cover may be removed by undoing the two screws at the This water heater is designed for bottom of the cover and sliding the single phase 240V a.c. supply only. The cover downwards to disengage the top electrical connection must comply with edge.
  • Page 10: Handover To The Customer

    Thermann Installer’s Manual 25L & 50L Electric Storage Water Heaters HANDOVER TO THE CUSTOMER Owner’s Guide: Disposal of Packaging: Ensure the customer receives the Dispose of the packaging and other Owner’s Guide supplied with the water transit protection responsibly using heater.
  • Page 12 028661 Rev.A...

This manual is also suitable for:

25thms13650thms124p50thms136