Preliminary Burner Settings - Dunkirk EMPIRE 3EWC0.80 Installation, Operation & Maintenance Manual

Oil-fired cast iron hot water
Table of Contents

Advertisement

BURNER
BOILER MODEL
MODEL
3EWC0.80(T)
AFG50MBAS
4EWC1.00(T) AFG50MDASN 1.00
4EWC1.25(T) AFG50MDASN 1.25
5EWC1.55(T) AFG50MDASN 1.55
BURNER
BOILER MODEL
MODEL
3EWC0.80(T)
EZ-1HP
4EWC1.00(T)
EZ-1HP
4EWC1.25(T)
EZ-1HP
5EWC1.55(T)
EZ-1HP
BURNER
BOILER MODEL
MODEL
3EWC0.80(T)
40F5
4EWC1.00(T)
40F5
4EWC1.25(T)
40F5
5EWC1.55(T)
40F5
Note: All burners fire at an overfire draft of -0.02 inches w.c. The burner settings provided are for initial startup only.
Final adjustment must be made using combustion test instruments.

PRELIMINARY BURNER SETTINGS

INPUT
INSERTION
DELAVAN OIL
RATE
DEPTH
NOZZLE
[gph]
0.80
2-1/4"
0.65-70°W
2-1/2"
0.85-60°A
2-1/2"
1.00-60°W
2-1/2"
1.25-60°B
CARLIN EZ-1HP
INPUT
INSERTION
DELAVAN OIL
RATE
DEPTH
NOZZLE
[gph]
0.80
2-1/4"
0.65-60°W
1.00
2-1/4"
0.85-60°B
1.25
2-1/4"
1.00-60°B
1.55
2-1/4"
1.25-60°B
RIELLO 40F5
INPUT
INSERTION
DELAVAN OIL
RATE
DEPTH
NOZZLE
[gph]
2-1/4"
0.80
0.70-90°B
2-1/4"
1.00
0.85-60°B
2-1/4"
1.25
1.10-60°B
2-1/4"
1.55
1.25-60°B
BECKETT AFG
PUMP
LOW
PRESSURE
FIRE BAFFLE
[psi]
150
YES
140
NO
155
NO
155
NO
PUMP
PRESSURE
HEAD BAR
[psi]
150
0.60/0.65
150
0.85/1.00
155
0.85/1.00
155
1.10/1.25
PUMP
TURBULATOR
PRESSURE
SETTING
[psi]
130
0
140
0
130
2
150
4
24
AIR
BURNER
HEAD
SHUTTER/
HEAD
SETTING
BAND
L1
N/A
10/1
V1
0
6/1
V1
0
10/1
V1
2
10/2
AIR
SETTING
50%
60%
75%
90%
AIR
SHUTTER
SETTING
1.70
2.25
3.00
3.25
PN 240013012, Rev. B [12/15/2020]
STATIC
PLATE
3-3/8"
2-3/4"
2-3/4"
2-3/4"