Page 3
6100-Gfast Multifunction Copper Tester Operation Manual Contents 8.3 Result Manager Menu ....... 51 8.4 Upload ............54 Preface ......... 5 8.5 Export............54 8.6 Delete............55 1.1 Before you begin .......... 5 1.2 Important notices ......... 5 Multimeter Tests ....... 56 1.3 Training ............
Page 4
6100-Gfast Multifunction Network Analyzer Operation Manual 15.2 POTS Auto Test ........142 15.3 User Auto Test ........144 15.4 Result Details ......... 151 15.5 Profile Details ......... 152 Setting Up DSL/IP Tests ..156 16.1 DSL Main Menu Page ......156 16.2 Test Configuration........
Page 5
Radiodetection service Please read this user manual in its entirety before center. More information can be found in the Appendix attempting to use the 6100-Gfast system as it contains or from your local Radiodetection representative. many important safety notices and warnings.
Page 6
Ethernet testing for qualifying FTTx service at the customer premises Configurable pass/fail The 6100-Gfast Test Set is housed in an aluminum results for automated testing enclosure with rubber over mold, which makes it ideal for field use. Its display is a back-lit LCD featuring 480 x ...
Page 7
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. The 6100-Gfast is equipped with a series of interfaces shown in the following views: Power LED...
Page 8
Primary Ring/B wire of phone line Fig. 3.6: 6100-Gfast connection identification Note: On the 6100-Gfast model, to test an ADSL 1/2/2+ Annex B interface, the unit uses the second pair (pins 2-5) in the DSL WAN RJ11 connector. When connecting the unit to a wall socket with a...
Page 9
6100-Gfast Multifunction Copper Tester Operation Manual CAUTION. When using the 6100-Gfast while Safety connected to the AC/DC adapter/charger, make sure you do not position the Information equipment so that it is difficult to disconnect the adapter/charger from the AC mains.
Page 10
Test results saved internally vs. USB To navigate through the items, use the arrow keys. There are two ways to turn off the 6100-Gfast: To confirm a choice or enter a menu, press Suspend: the next time you turn your unit on, you will quickly return to your work ...
Page 11
6100-Gfast Multifunction Copper Tester Operation Manual 5.3 Keypad If Enabled, press and hold the key to capture a screenshot on any page. A popup message is displayed saying Screenshot captured, Press “Yes” to save or “No” to continue to Help. Pressing No will also discard the screenshot.
Page 12
6100-Gfast Multifunction Network Analyzer Operation Manual Setting Up the 6100-Gfast 6.1 Home Home presents the main menu page which allows you to navigate between Copper Test, DSL/IP Tests, System Settings and the Wi-Fi Test using the left/right arrow keys on the keypad.
Page 13
The Remote Display function allows you to connect Press after your selection to confirm. the 6100-Gfast to your computer remotely, using PC Use the up/down arrow keys to navigate TightVNC or RealVNC client application, and a between the available languages, then press Bluetooth or USB connection.
Page 15
Note: If you hold down for 12 seconds or more, the a. For the Date and Time, an edit screen 6100-Gfast may reset the date and time to is displayed with descriptive function incorrect values. Once the unit is powered back keys.
Page 16
6100-Gfast Multifunction Network Analyzer Operation Manual Possible options are as follows: LCD backlight turns off after system idles (no keys pressed) for 10 min. VDSL2MOD (Support VDSL2 test) Unit switches to suspend mode after timeout: PING (Support Ping and IP login) 10 min.
Page 17
6100-Gfast Multifunction Copper Tester Operation Manual Stressed Balance Test Far End Device Test Control Return Loss ADSL+ and VDSL2 Data Rate Prediction VDSL2-35b Data Rate Prediction UFED Control Platform Options This screen lists all the Platform Configured Options which are present on the unit.
Page 18
Yellow icon indicates that the Wi-Fi Upload Enable dongle is powered up and ok, but that the 6100-Gfast is not connected to any The Upload Enable function allows you to upload your test result files. (FTP Result Upload option must be enabled.)
Page 19
Transfer Type is set to Binary, transferring Note: If you select a network from the list of previously files as a binary stream of data. selected networks (last 3), the 6100-Gfast will try to join that network using the credentials saved ...
Page 20
Note: Only Wi-Fi channels 1-11 are supported. Password opens the alphanumeric editor To connect your 6100-Gfast to a Wi-Fi network: screen allowing you to enter the desired Wi-Fi network’s password. Join function key replaces 1. Press the down arrow key to highlight the list Done on the editor screen.
Page 21
Local Mac Address is the internal MAC options or the alphanumeric editor screen and address of the unit: either 6100-Gfast or User use the navigation keys to scroll through. Defined. ...
Page 22
6100-Gfast Multifunction Network Analyzer Operation Manual When Wi-Fi or Ethernet are selected, their respective Sort RSSI button allows you to toggle the RSSI icons are displayed in the top right-hand corner of the signal strength values by ascending and navigation bar.
Page 24
6100-Gfast Multifunction Network Analyzer Operation Manual Setting Up Copper Tests The 6100-Gfast is designed to test basic twisted pair quality, identify and locate faults, and troubleshoot noise and signal issues. These measurements offer a quick and thorough method to determine if the cable is capable of supporting xDSL technology.
Page 25
6100-Gfast Multifunction Copper Tester Operation Manual pressing Yes, or skipped by pressing You can terminate the process by pressing Cancel. Copy from USB allows you to copy all profiles found on an external USB device to the unit. ...
Page 26
6100-Gfast Multifunction Network Analyzer Operation Manual Each test displays a sub-menu of test icons to select Noise Tests Profile Details and view. To select a test: 1. Press the up/down left/right arrow keys on the keypad to select an icon.
Page 27
6100-Gfast Multifunction Copper Tester Operation Manual Frequency Tests Profile Details To navigate between the test profiles: 1. Press the left/right arrow keys on the keypad to select an icon. The profile details Frequency Tests main menu allows you to view the test threshold and parameters of the 2.
Page 28
6100-Gfast Multifunction Network Analyzer Operation Manual 1. Press the up/down left/right arrow keys on the 7.3 Setup keypad to select an icon. The Setup function allows you to set up parameters 2. Press to confirm your selection. common to all tests.
Page 29
6100-Gfast Multifunction Copper Tester Operation Manual 7.4 Phone Book To select a group and entry: 1. Press the up/down arrow keys to highlight the desired entry and press . The Group # in Use is updated with the current selection.
Page 30
6100-Gfast Multifunction Network Analyzer Operation Manual Group ID displays the group ID number. This is the only parameter that cannot be modified however you can navigate between the available phone groups. Entry Name is the name of the entry in the Phone Book.
Page 31
6100-Gfast Multifunction Copper Tester Operation Manual Clone Group The Clone Group page allows you to copy the details of an existing entry to a new group entry in the Phone Book. The page lists all entries by Group ID. The list can display a maximum of 50 entries.
Page 32
The Dialer function provides a dial-up path from the loaded one. 6100-Gfast to another tester (or quiet termination or silent switchman) through a switched circuit network. DTMF (dual-tone multi-frequency) transmission is 5.
Page 33
6100-Gfast Multifunction Copper Tester Operation Manual last dialed lists, without exiting the current test application. To access the Dialer function: 1. On the Home pane use the up/down arrow keys to highlight Copper Test, then press 2. From the Copper Main or Multimeter (if FED...
Page 34
6100-Gfast Multifunction Network Analyzer Operation Manual Note: Alphabets on the keypad are for reference only. Pressing any of the buttons will not show the To dial a number: alpha-character in the text box. 1. Use the up/down arrow keys to highlight an...
Page 35
6100-Gfast Multifunction Copper Tester Operation Manual The Select Entry read-only page lists entries by Group Add function key adds the new group entry to ID and Entry Name/Type. There is 1 group of 3 factory the Phone Book. default entries. The Phone Book can include a maximum of 50 groups.
Page 36
6100-Gfast Multifunction Network Analyzer Operation Manual Save Cable Book 2. Press to cancel your selection and go To navigate between the cable book functions: back to the Cable Book menu. 1. Press the up/down left/right arrow keys on the Cable Details keypad to select an icon.
Page 37
6100-Gfast Multifunction Copper Tester Operation Manual VOP V/2 m/µs is the velocity of propagation for Cable Gauge is the gauge system for the cable in m/µs divided by 2 measuring wire sizes in AWG (American Wire Gauge0 units or mm (metric wire size).
Page 38
6100-Gfast Multifunction Network Analyzer Operation Manual Clone Cable The Clone Cable page allows you to copy the cable details of an existing entry from the selected Cable Book to a new cable entry in the CableBookSettings. The page lists all entries by ID, Cable Name, and Cable Fill.
Page 39
7.7 Application Settings Before executing the copper tests, set up the software 5. Press Cancel to remove the message. settings and values for the cables. The 6100-Gfast allows you to save standard parameter settings to different profiles and reuse them as needed.
Page 40
6100-Gfast Multifunction Network Analyzer Operation Manual Test Startup Mode lists the test startup type: General Auto (default) automatically starts a The General tab allows you to configure the unit with test when you select the respective specific measurement values and graph viewing icon from the test sub-menu pane and settings.
Page 41
6100-Gfast Multifunction Copper Tester Operation Manual Cable Gauge Unit allows you to select Standard either AWG or mm wire gauge. AWG is the default for ANSI and mm for ITU. If you select AWG, only AWG cables will be displayed in the Cable Book\Select Cable list and test pages.
Page 42
6100-Gfast Multifunction Network Analyzer Operation Manual Identification CROSSBOX, and FRAME. When any of these are selected, the Delete and Accept buttons are disabled. A maximum of 20 different entries can be added. The Identification tab allows you to preset values to...
Page 43
The tab allows you to configure values for the buzzer settings. However, due to the risk of electrical shocks, 4. Press the up/down arrow keys to select the the 6100-Gfast detects high voltages on any pair of option and press to confirm your selection.
Page 44
Pass/Fail status of the last compensation done. Note: When the 6100-Gfast raises the hazardous voltage flag, it opens the relays and you will have Note: Always perform a test lead compensation if the to press Start/Stop on the keypad to re initialize test leads have recently been removed or the unit.
Page 45
When FED is Auto or Manual and you start a test, the 6100-Gfast will warn you if the FED battery level is low. Select OK to close the message and run the test. Also, if the FED is...
Page 46
6100-Gfast Multifunction Network Analyzer Operation Manual FED Type is enabled when FED is set to Auto Manual Setup includes 5 options: or Manual. If Auto is selected, you can choose Open 0 between TS125 or UFED IIB. T-R/A-B Shorted 1 ...
Page 47
6100-Gfast Multifunction Copper Tester Operation Manual 4. Press to confirm the value. Noise To select the parameter values: The Noise tab allows you to set the FED States for all 1. Press the up/down arrow keys to highlight the noise tests, and lists the default value for NEXT test.
Page 48
6100-Gfast Multifunction Network Analyzer Operation Manual Frequency Other The Frequency tab lists the default FED States set for frequency tests and allows you to set the values for the following: The Other tab displays the default FED States set for ...
Page 49
You can save a snapshot of test results into a result file during or after a test performed with the 6100-Gfast. Result File Storage Location gives Each copper test includes a Save Result tab to do so.
Page 50
6100-Gfast Multifunction Network Analyzer Operation Manual To set parameter values and save results: 1. Press the left/right and up/down arrow keys to highlight the desired parameter. 2. Press to display the list or select the value. 3. Press the up/down arrow key to highlight the desired value.
Page 51
Results 8.1 Result Manager You can view, Upload, Export, and Delete any of your saved results with the 6100-Gfast Copper Test Set, by highlighting the Result Manager icon from the Copper Main pane and pressing To open previously saved test results: 1.
Page 52
6100-Gfast Multifunction Network Analyzer Operation Manual based on the cable temperature of the test lead. Editable Identification Fields display values from the loaded file. You can edit all fields using the editor screen or by selecting an entry from the list box.
Page 53
6100-Gfast Multifunction Copper Tester Operation Manual Result Details Test Identification is the test type of the group, for example Current. The Results Details page allows you to view measured results for each lead combination and cable parameters of the selected test.
Page 54
All files previously saved and export the results in a selected Report Format. Storage Location gives you the option of exporting your results to either the 6100-Gfast internal memory or USB device. Select Files is either None or All. None removes all check marks allowing you to select one or more files, or All.
Page 55
6100-Gfast Multifunction Copper Tester Operation Manual 10. Press the down arrow key to press the Export button. 8.6 Delete The Delete page allows you to delete a selected File Name or All selected result files previously saved in the 6100-Gfast internal memory only.
Page 56
6100-Gfast Multifunction Network Analyzer Operation Manual Multimeter Tests The purpose of the Multimeter tests function is to detect AC/DC voltages and currents, measure resistance and capacitance in a loop, and stress test the loop. To access Multimeter tests: From the Copper Main pane, highlight Multimeter and press to open the Multimeter menu.
Page 57
6100-Gfast Multifunction Copper Tester Operation Manual To start/stop a test: 1. Press the up/down left/right arrow keys on the keypad to select the desired test icon. 2. Press to confirm your selection. 3. The test will start automatically if the Setup/Application Settings - Test Startup Mode is set to Auto.
Page 58
6100-Gfast Multifunction Network Analyzer Operation Manual Continuous AC Page 3. Press on a value to open a list box of options. The Continuous AC function measures each pair, displaying and updating results in real time, until you 4. Press to confirm the value.
Page 59
6100-Gfast Multifunction Copper Tester Operation Manual 2. Press the left/right arrow keys to view and To select the parameter values: select the options. 1. Press the up/down arrow keys to highlight the desired parameter. 2. Press the left/right arrow keys to view and 3.
Page 60
6100-Gfast Multifunction Network Analyzer Operation Manual Termination Resistance is a read-only value Type is the threshold limit for each pair: either of 430 Ω that defines how much resistance the Maximum or Minimum. tester uses to connect to the line.
Page 61
6100-Gfast Multifunction Copper Tester Operation Manual Press the Snapshot function key. Selected Pair allows you to select All Pairs or a single wire pair for measurement. Termination Resistance is a read-only value Continuous AC and Continuous DC are run of 430 Ω...
Page 62
6100-Gfast Multifunction Network Analyzer Operation Manual It is also valuable to apply a short across T/A-R/B at the Snapshot far end, and then measure the round trip loop resistance, in which case you will see that low values with the far-end short are applied (≤ 2500 Ω, depending on loop length and condition).
Page 63
6100-Gfast Multifunction Copper Tester Operation Manual 1. Press the up/down arrow keys to highlight the Result displays a snapshot of the pass/fail desired parameter. status, Resistance and Length for each selected wire pair. 2. Press the left/right arrow keys to view and ...
Page 64
6100-Gfast Multifunction Network Analyzer Operation Manual an entry (with its associated be 2-3 % when possible (97-98 % balance). There will parameters) from the current Cable be low-Ohm values when measuring resistance with a Book, to use for testing. The selection short at the far end.
Page 65
6100-Gfast Multifunction Copper Tester Operation Manual 2. Press the left/right arrow keys to view and Result Details select the options. The Results Details read-only page displays the Resistance results for each lead combination and the pass/fail status for Resistive Balance in Ω and %.
Page 66
6100-Gfast Multifunction Network Analyzer Operation Manual Current Test displays the test being 9.6 Isolation measured. Here you can switch to another test The Isolation test, also known as a leakage test, is a from the given list. However, this action will type of resistance test run over a period of time to look terminate the ongoing measurement test.
Page 67
6100-Gfast Multifunction Copper Tester Operation Manual Note: The test should be run with an open circuit at the far end. Type is the threshold limit for each pair: either Maximum or Minimum. Note: If UFED Control option is enabled, due to its ...
Page 68
6100-Gfast Multifunction Network Analyzer Operation Manual Result displays a snapshot of the pass/fail status, Resistance and a Soak Counter for To access TDR from Multimeter tests: each selected wire pair. While running the test, the counter displays the soak period by the 1.
Page 69
6100-Gfast Multifunction Copper Tester Operation Manual Note: The accuracy of the 2 Terminal Capacitance results/length could indicate intermittent or wet faults, Measurement is impacted by the use of the or a partial open. FED, and the 3 Terminal (default) method is recommended to be used instead.
Page 70
9.8 Station Ground The Station Ground test measures and displays the resistance value and pass/fail status of the ground resistance between the 6100-Gfast and the CO (Central Office). A provisioned POTS circuit is required for this test to work properly.
Page 71
6100-Gfast Multifunction Copper Tester Operation Manual ground potential, and some noise may couple onto communications circuits. Depending on where you measure the station ground, check the bonding lugs on cross-boxes, pedestals, and electronics/remotes, as well as cable and terminal bonds. These all need to be good quality and tight. If you think the ground rod/plane is inadequate, please consult your support, management, or procedures.
Page 72
6100-Gfast Multifunction Network Analyzer Operation Manual 2. Press the left/right arrow keys to view and Test Status displays the current state of select the options. measurement or an error message. To select the Station Ground parameter values: 3. Press...
Page 73
6100-Gfast Multifunction Copper Tester Operation Manual that may otherwise be hidden with the normal VF/AC 2. Highlight Resistive Balance and press Balance test. launch the test. It does first require a T-R-G/A-B-Earth short at The test is very similar to the classic stress test well the far end.
Page 74
6100-Gfast Multifunction Network Analyzer Operation Manual Note: Disabling Good Balance will also disable the Threshold Settings button opens a new page Marginal Balance threshold, even if you that allows you to set the Stressed Balance Enabled it. Threshold for the test.
Page 75
Features Pair Detective runs two unique tests found nowhere SmartR features, consisting of Pair Detective and else in the 6100-Gfast: Corrosion and Wet detect. FaultMapper, are a line of intelligent tests that go Corrosion detect identifies the presence of one-sided...
Page 76
6100-Gfast Multifunction Network Analyzer Operation Manual a high-resistive versus normal fault by Grounds/high resistive ground changing the threshold parameters. Opens/possible high resistive open Note: Individual test parameters can be modified by Imbalanced pair accessing their respective test pages.
Page 77
6100-Gfast Multifunction Copper Tester Operation Manual Cable Gauge identifies the gauge system for Foreign DC Voltage sets the maximum foreign measuring wire sizes in AWG (American Wire DC voltage value. Default is 4 V which is fine Gaugeunits or mm (metric wire size).
Page 78
6100-Gfast Multifunction Network Analyzer Operation Manual Multimeter The TDR test displays the line trace and is continuously on and ready to use. It displays and updates results in The Multimeter page displays the raw values used by real time, in either Portrait or Landscape Mode Pair Detective to identify a fault on the summary (recommended), until you stop the test.
Page 79
6100-Gfast Multifunction Copper Tester Operation Manual range selected. (A manual control TDR is available in the TDR sub-menu from the Copper Main menu). To select the parameter values in Portrait Mode: VOP allows you to change the velocity of 1.
Page 80
6100-Gfast Multifunction Network Analyzer Operation Manual To select the parameter values in Landscape Mode: 1. Press the desired function key. 2. For Parameters and Cable Setup, press the up/down arrow keys to highlight the desired parameter. 3. Press the left/right arrow keys to view, select the options, or increase/decrease values.
Page 81
6100-Gfast Multifunction Copper Tester Operation Manual FaultMapper can identify and/or locate the following: 10.3 FaultMapper Shorts The FaultMapper is a graphical snapshot of the pair to locate and identify line faults. It combines and analyzes Grounds (strap required to determine distance) the results of several different tests including ...
Page 82
6100-Gfast Multifunction Network Analyzer Operation Manual Estimated Length displays the cable length when the cable is open. Note: The cable length may include the Bridge Tap length: remove the Bridge Tap for better accuracy. Fault Status displays the number of faults detected (or No fault detected) after running the test.
Page 83
6100-Gfast Multifunction Copper Tester Operation Manual Cable Temperature allows you to change the temperature of the cable under test in either °F or °C. To select the parameter values: 1. Press the up/down arrow keys to highlight the desired parameter.
Page 84
6100-Gfast Multifunction Network Analyzer Operation Manual Cable Type displays the ID, Cable Name and Profile Name is the file name of the selected Fill, (with its associated parameters) from the saved results. current Cable Book, used for testing.
Page 85
6100-Gfast Multifunction Copper Tester Operation Manual 11.1 Noise Tests Main Page Noise Tests The purpose of the noise tests is to perform VF / WB (voice frequency / wideband) noise and level measurements. The Noise Tests menu allows you to select and run the displayed tests: ...
Page 86
6100-Gfast Multifunction Network Analyzer Operation Manual 11.2 VF Noise To select the parameter values: The VF Noise test allows you to measure the amount 1. Press the up/down arrow keys to highlight the of unwanted or disturbing energy introduced into a loop desired parameter.
Page 88
6100-Gfast Multifunction Network Analyzer Operation Manual Current Group is the current test group name, Result Details for example Noise. The Results Details read-only page displays the VF Current Test displays the test being Noise value and the pass/fail status.
Page 89
6100-Gfast Multifunction Copper Tester Operation Manual 2. Press the left/right arrow keys to view and Result Details select the options. 3. Press on a value to open a list box of options. 4. Press to confirm the value. Power Influence Threshold Settings The Threshold Settings page allows you to set the Threshold Power Influence values for the test.
Page 90
6100-Gfast Multifunction Network Analyzer Operation Manual displayed after 1 s and then periodically 11.4 VF Impulse Noise refreshed, until you stop the test. The VF Impulse Noise test allows you to measure Test Status displays the current state of voice frequency impulse noise on the circuit under test.
Page 91
6100-Gfast Multifunction Copper Tester Operation Manual To set threshold values: 1. Press the up/down arrow keys to highlight the desired parameter. 2. Press the left/right arrow keys to view and select the options. 3. Press on a value to open a list box of options or the alphanumeric editor screen and use the navigation keys to scroll through.
Page 92
6100-Gfast Multifunction Network Analyzer Operation Manual To select the parameter values in Portrait Mode: Threshold Settings button opens a new page that allows you to set the RMS Noise 1. Press the up/down arrow keys to highlight the Threshold parameters for the test.
Page 93
6100-Gfast Multifunction Copper Tester Operation Manual 4. Press to confirm the value. WB PSD Noise Threshold Settings The Threshold Settings page allows you to set the RMS Noise Threshold parameters for the test. Select Files is either None which removes all check marks allowing you to select one or more Masks, or All.
Page 94
6100-Gfast Multifunction Network Analyzer Operation Manual 6. In the list, press the up/down arrows to 1:1 resets the x-axis and y-axis limits to full scale. highlight the desired files and press select/deselect a Mask. Landscape Mode function key allows you to 7.
Page 95
6100-Gfast Multifunction Copper Tester Operation Manual Bridging if additional termination resistance is used to bridge onto live circuits with minimal interruption. Termination Resistance lists the resistance of the dummy load connected to the line. Test Duration allows you to set the length of time to run the test from a list of values.
Page 96
6100-Gfast Multifunction Network Analyzer Operation Manual Select Graph button changes to Graph Selected when pressed and opens a new selection of function Profile Details keys, which allow you to maneuver the graph as The WB Impulse Noise Profile Details read-only page...
Page 97
6100-Gfast Multifunction Copper Tester Operation Manual Spot The Confirmation window is prompted before every NEXT test is started if you selected Yes for the Show hookup diagram. You can select No to hide the diagram next time you run the test.
Page 98
6100-Gfast Multifunction Network Analyzer Operation Manual To select the Spot parameter values: Spot Result Details 1. Press the up/down arrow keys to highlight the The Spot Results Details read-only page displays the desired parameter. saved pass/fail status, NEXT and Frequency (TX) values.
Page 99
6100-Gfast Multifunction Copper Tester Operation Manual Bandwidth allows you to select the bandwidth of the frequency range for the test. Available frequency bandwidths are: 2.2 MHz, 8 MHz, 12 MHz, 17.6 MHz and 30 MHz. Termination Resistance lists a choice of resistance values for the termination of the signal.
Page 100
6100-Gfast Multifunction Network Analyzer Operation Manual 1. Press the up/down arrow keys to highlight the 4. Press to confirm the value. desired parameter. 2. Press the left/right arrow keys to view and select the options. Spectrum Result Details The Spectrum Results Details read-only page displays the pass/fail status and test results in graphical 3.
Page 101
6100-Gfast Multifunction Copper Tester Operation Manual Pan - use left/right arrow keys to pan the x-axis and the up/down arrow keys to pan the y-axis. 1:1 resets the x-axis and y-axis limits to full scale. Return To Test removes these function keys and returns to the Spectrum results page.
Page 102
6100-Gfast Multifunction Network Analyzer Operation Manual The Frequency Tests menu allows you to select and Frequency run the displayed tests: Tests VF/AC Balance The purpose of the frequency tests is to perform VF WB Balance (voice frequency) and WB (wide band) level ...
Page 103
6100-Gfast Multifunction Copper Tester Operation Manual VF/AC Balance Active Threshold Settings The Threshold Settings page allows you to set the Active VF/AC Balance Threshold values for the test. Current Group is the current test group name, for example Frequency Tests.
Page 104
6100-Gfast Multifunction Network Analyzer Operation Manual from the given list. However, this action will terminate the ongoing measurement test. Noise Filter displays the type of noise filter used. Power Line Frequency displays the frequency value of the power line.
Page 105
6100-Gfast Multifunction Copper Tester Operation Manual VF/AC Balance sets the passive balance threshold. 12.3 WB Balance Type is the threshold limit: either Maximum or The wideband balance test ensures that the balance Minimum. ratio for the twisted pair complies with applicable ...
Page 106
6100-Gfast Multifunction Network Analyzer Operation Manual from the given list. However, this action will bandwidth, represented by a horizontal terminate the ongoing measurement test. yellow line. If Mask is enabled for the selected bandwidth, then: Bandwidth allows you to select the frequency...
Page 107
6100-Gfast Multifunction Copper Tester Operation Manual Bandwidth and Termination Resistance To set threshold values: values from a list of options. 1. Press the up/down arrow keys to highlight the desired parameter. To select the parameter values in Landscape Mode: 2. Press the left/right arrow keys to view and select the options.
Page 108
6100-Gfast Multifunction Network Analyzer Operation Manual bandwidths: ISDN, HDSL, SHDSL, ADSL1/2, Pan - use left/right arrow keys to pan the x-axis ADSL2+, VDSL2-8, VDSL2-12, VDSL2-17, and the up/down arrow keys to pan the y-axis. VDSL2-30, or VDSL2-35. 1:1 resets the x-axis and y-axis limits to full ...
Page 109
6100-Gfast Multifunction Copper Tester Operation Manual An attenuation vs. frequency curve is WB Attenuation Threshold Settings added to the graph A table displaying the Total equivalent The Threshold Settings page allows you to set the Calculated Attn and the Measured WB Attenuation threshold values for the test.
Page 110
6100-Gfast Multifunction Network Analyzer Operation Manual To select the parameter values: Cable Configuration 1. Press the up/down arrow keys to highlight the desired parameter. The Cable Configuration page is only required if using 2. Press the left/right arrow keys to view and theoretical calculated attenuation pass/fail.
Page 111
6100-Gfast Multifunction Copper Tester Operation Manual Select Graph button changes to Graph Selected when pressed and opens a new selection of function keys which allow you to maneuver the graph as follows: Cursor - press the left/right arrow keys to decrease/increase the values by moving the cursor.
Page 112
6100-Gfast Multifunction Network Analyzer Operation Manual Return Loss Threshold Settings The Return Loss Threshold Settings page allows you to set the Loss Threshold for each pair. The threshold is a programmable value you can use as an on-screen indicator in each test when a measured value is too high or too low.
Page 113
6100-Gfast Multifunction Copper Tester Operation Manual bandwidths: ISDN, HDSL, SHDSL, ADSL1/2, Single Frequency Result Details or ADSL2+. The Results Details read-only page displays the Termination Resistance lists a choice of pass/fail status, Return Loss and Frequency (TX) resistance values for the termination of the values.
Page 114
6100-Gfast Multifunction Network Analyzer Operation Manual To set threshold values: 3. Press on a value to open a list box of options. 1. Press the up/down arrow keys to highlight the desired parameter. 4. Press to confirm the value. 2. Press the left/right arrow keys to view and select the options.
Page 115
6100-Gfast Multifunction Copper Tester Operation Manual and place it in the middle of the current 12.6 Load Coils x-axis limits. The Load Coils test allows you to detect the presence Zoom references the middle of the x/y of load coils, which are detrimental to the use of DSL axis and not the cursor position.
Page 116
6100-Gfast Multifunction Network Analyzer Operation Manual Cable Temperature allows you to change the temperature of the cable The Load Coils TDR function provides a shortcut to the under test in either °F or °C. TDR test. A dialog box opens, warning that you are ...
Page 117
6100-Gfast Multifunction Copper Tester Operation Manual cursor and place it in the middle of the current Current Test displays the test being x-axis limits. measured. Here you can switch to another test from the given list. However, this action will ...
Page 118
6100-Gfast Multifunction Network Analyzer Operation Manual To select the parameter values: Send Tone 1. Press the up/down arrow keys to highlight the The Send Tone (TX) pane allows you to configure and desired parameter. transmit a tone to a downstream device in the loop.
Page 119
6100-Gfast Multifunction Copper Tester Operation Manual To select the parameter values: Profile Details Receive Tone 1. Press the up/down arrow keys to highlight the The Profile Details page displays read-only Receive desired parameter. Tone Test Parameters. 2. Press the left/right arrow keys to view and select the options.
Page 120
6100-Gfast Multifunction Network Analyzer Operation Manual To select the parameter values: Single Tone 1. Press the up/down arrow keys to highlight the desired parameter. 2. Press the left/right arrow keys to view and select the options. 3. Press on a value to open a list box of options or the alphanumeric editor screen and use the navigation keys to scroll through.
Page 122
6100-Gfast Multifunction Network Analyzer Operation Manual Up = y-axis zoom in. 3. Press on a value to open a list box of options and use the navigation keys to scroll Down = y-axis zoom out. through. Pan - use left/right arrow keys to pan the x-axis and the up/down arrow keys to pan the y-axis.
Page 123
6100-Gfast Multifunction Copper Tester Operation Manual Profile Details The Profile Details page displays read-only Test Parameters for both the Single and Multiple RX Tone with FED tests, and may contain the following entries: Profile Name (only displayed in Results Manager) is the file name of the selected saved results.
Page 124
6100-Gfast Multifunction Network Analyzer Operation Manual 3. xTalk (crosstalk) TDR allows you to locate split pairs between tip (A) and ring (B) copper wires which may be causing service disruptions. The test transmits on pair one and receives on pair The TDR (time domain reflectometer) test is a useful two to locate the split pairs.
Page 125
6100-Gfast Multifunction Copper Tester Operation Manual Live turns Peak Hold off clearing Range allows you to set the range from the previously collected given list. minimum/maximum measurement Gain allows you to select a gain test parameter values. This is the default.
Page 126
6100-Gfast Multifunction Network Analyzer Operation Manual 1:1 resets the x-axis and y-axis limits to full scale. Return To Test removes these Landscape Mode generates the following function keys and displays the previous function keys: ones. Portrait Mode is used to change the ...
Page 129
6100-Gfast Multifunction Copper Tester Operation Manual Load Coil The Continuous function displays the line trace and is continuously on and ready to use. It displays and updates results in real time, in either Portrait or Landscape Mode, until you stop the test. The last valid results then remain displayed.
Page 130
6100-Gfast Multifunction Network Analyzer Operation Manual Peak Only turns Peak Hold ON To select the parameter values in Portrait Mode: displaying only Peak traces with no 1. Press the up/down arrow keys to highlight the offset. desired parameter. Cable Setup button opens a new page that 2.
Page 131
After the TDR test has been stopped. material the cable is filled with: Aircore, Jelly, Pulp, 5 PR, or 2 PR. Setup in the Cable Book. Traces may be loaded from either 6100-Gfast internal memory or USB. Velocity of Propagation is the velocity of propagation for the cable.
Page 132
6100-Gfast Multifunction Network Analyzer Operation Manual Live and Peak turns Peak Hold ON 13.5 Result Details and collects minimum/maximum The Results Details page displays the TDR test result measurement values, displaying all 3 cable parameters and the last viewed Range, cursor, traces.
Page 133
6100-Gfast Multifunction Copper Tester Operation Manual To select the parameter values in Portrait Mode: view the Cable Type, Cable Fill, Velocity of Propagation, and Cable 1. Press the up/down arrow keys to highlight the Temperature. For more information, desired parameter.
Page 134
6100-Gfast Multifunction Network Analyzer Operation Manual Load Trace The Load Trace function in the Results Details is the same as previously described. Please see Load Trace on page 131 for more information. 13.6 TDR Profile Details The Profile Details page displays read-only TDR Test Parameters.
Page 135
6100-Gfast Multifunction Copper Tester Operation Manual Resistance fault locator (RFL) testing is a powerful 6100 means to locate resistive faults such as shorts, grounds, and battery crosses. Before performing RFL tests, install the strap(s) at the other end of the cable. Use of an oscillator or toner as a far end strap is not recommended, as it will induce errors.
Page 136
6100-Gfast Multifunction Network Analyzer Operation Manual If the test reports that it cannot detect the strap when the measured loop resistance is >10 k Ohms, this may mean: There is no strap connected. 6100 There is a strap, but the cable is too long and has a loop resistance >10 k...
Page 137
6100-Gfast Multifunction Copper Tester Operation Manual Resistance to strap (RTS). Distance from fault to strap (DFTS). Resistance from fault to strap (RFTS). Resistance to fault (RTF). Distance to fault (DTF). Faulted cable (FC). Resistance at fault (Rf) is resistance from the fault to the resistance wire.
Page 138
Settings. The K-Test diagram can display some of the following elements: R/A-T/B-G/E wire connectors. Distance/resistance to strap (DTS/RTS): distance/resistance from the 6100-Gfast to the strap (far end). Distance/resistance from fault to strap (DFTS/RFTS). Distance/resistance to fault (DTF/RTF): distance/resistance from the 6100- Gfast to the fault.
Page 139
6100-Gfast Multifunction Copper Tester Operation Manual 14.4 RFL Cable Setup 3. Press on a value to open a list box of options The Cable Setup page allows you to set cable or the alphanumeric editor screen and use the parameters for an RFL test. Settings are shared by navigation keys to scroll through.
Page 140
6100-Gfast Multifunction Network Analyzer Operation Manual User Name/ID Test From/To Job ID Customer Name Circuit ID Comments Function keys: Save keeps any current changes with the current file name. Save As saves the current changes under a different file name that you can configure in the editor screen.
Page 141
6100-Gfast Multifunction Copper Tester Operation Manual K-Test The Results Details read-only page displays the K- Test RFL results using text and a connection diagram. Test Identification displays the current test, for example RFL. Cable Setup button opens a new page displaying the cable parameters of the RFL test.
Page 142
6100-Gfast Multifunction Network Analyzer Operation Manual 15.2 POTS Auto Test Copper The purpose of the POTS Auto Test is to detect the Auto Tests loop current and measure the voice frequency parameters in a copper telephone loop. This test allows...
Page 143
6100-Gfast Multifunction Copper Tester Operation Manual Phone Book Parameters: Phone Book Group allows you to select the Group # from a list of phone book groups that include mW tone entries. Milliwatt Tone Entry displays at least 1 mW tone entry number from the selected Phone Book Group.
Page 144
6100-Gfast Multifunction Network Analyzer Operation Manual To access User Auto Test: 1. From the Copper Main menu, use the up/down, left/right arrow keys to highlight Auto Test and press 2. Highlight User Auto Test and press to start the test.
Page 145
6100-Gfast Multifunction Copper Tester Operation Manual 2. Press the left/right arrow keys to view and VF Noise measures voice frequency noise in select the options. the line. Power Influence measures the effects that 50 Hz and 60 Hz power line (AC Mains) 3.
Page 146
6100-Gfast Multifunction Network Analyzer Operation Manual Circuit ID allows you to create/edit a unique identifier for the circuit under 3. Press on a value to open a list box of test. options. Comments allow you to add any 4. Press to confirm the value.
Page 147
6100-Gfast Multifunction Copper Tester Operation Manual Export button confirms if the Report Multimeter 2 Result File Name is saved successfully. If a USB device is not inserted, the following warning dialogue box appears: USB device not present. To set parameter values and save results: 1.
Page 148
6100-Gfast Multifunction Network Analyzer Operation Manual 3. Press to confirm the test. VF Noise measures voice frequency noise in the line. Select Graph button changes to Graph VF Impulse Noise - High, Mid, Low counts, Selected when pressed and opens a new respective detection levels, and Elapsed Time.
Page 149
6100-Gfast Multifunction Copper Tester Operation Manual to Marginal results. If the measurement is greater/less than the marginal test threshold, represented by a horizontal red line, the status is fail. Otherwise, the status is pass. To select a test: 1. In the Select Test parameter, press the left/right arrow keys to view and select the options.
Page 150
6100-Gfast Multifunction Network Analyzer Operation Manual Left = x-axis zoom out. Up = y-axis zoom in. Down = y-axis zoom out. Pan - use left/right arrow keys to pan the x-axis and the up/down arrow keys to pan the y-axis.
Page 151
6100-Gfast Multifunction Copper Tester Operation Manual Cable Fill displays the type of material the Recalculate button allows you to recalculate cable is filled with: Aircore, Jelly, Pulp, 5 PR, data rates after editing the following Test or 2 PR. Setup in the Cable Book.
Page 152
6100-Gfast Multifunction Network Analyzer Operation Manual Multimeter 1 Result on page 147, Multimeter 2 Result on page 147, Noise Result on page 148, Noise Result Graph on page 148, and Frequency Result on page 149 for more information. Summary The Result Details Summary page displays the overall pass/fail status of all tests selected for auto testing.
Page 153
6100-Gfast Multifunction Copper Tester Operation Manual FED displays Enabled or Disabled. Noise 1 Parameter The Noise 1 Parameter page displays the profile details of the parameter values for the VF Noise, Power Influence, and VF Impulse Noise tests. To access the test parameter and threshold results: 1.
Page 154
6100-Gfast Multifunction Network Analyzer Operation Manual Multimeter 1 Threshold The Multimeter 1 Threshold page displays the AC/DC Voltage and Current Test Thresholds and limits for each Pair. TDR Parameter The TDR Parameters page displays the parameter values of the TDR results.
Page 155
6100-Gfast Multifunction Copper Tester Operation Manual Noise Threshold Frequency Threshold 2 The Frequency Threshold 2 page displays WB The Noise Threshold page displays the Test Attenuation and Return Loss test threshold values Thresholds and limits for the following tests: and limits.
Page 156
Setting Up DSL/IP Tests 16.1 DSL Main Menu Page The 6100-Gfast supports 3 types of test applications: Auto Test, Manual Test, and Ethernet Test. Configuration parameters for all 3 test applications are saved into a test configuration profile. A default profile...
Page 157
Software Options and icon for each test: Auto Test, Manual, and Ethernet. model Information. The 6100-Gfast-Bond unit does ADSL Annex A, VDSL2 Bonding, and Vectoring. ADSL Annex A is on pair 1 and bonding uses pair 1 and pair 2.
Page 158
If Auto Resync is disabled, any time the test VDSL2-35b if enabled. loses sync, the result status will be fail and the The 6100-Gfast unit does ADSL Annex B and UR2 test will stop automatically. which can be configured in Setup\Modem ...
Page 159
IPv6 (DHCP). gateway. Local Mac Address is the internal MAC Verify Gateway can be set to Enable or address of the unit: either 6100-Gfast or User Disable. Defined. Subnet Mask is the network address used to ...
Page 160
6100-Gfast Multifunction Network Analyzer Operation Manual To configure the setup options: Note: If the DSL WAN has an IP address on a specific subnet (for example 192.168.x.y) and the 1. Press the up/down arrows to select the desired Ethernet LAN port is enabled, configure the parameter.
Page 161
6100-Gfast Multifunction Copper Tester Operation Manual The IPv6 LAN Setup tab is available only in Manual for VDSL2-35b - D/S can be 350 Test Setup and when the Access Mode set in Mbit/s, U/S is 50 Mbit/s. Connection Setup is set to IPv6 (DHCP). This page ...
Page 162
Enable/Disable. IPTV Test supports STB (set-top box) emulation mode over DSL and Ethernet interfaces enabling the 6100-Gfast to join and 3. Press on any value to open the list box to leave multicast IPTV streams. When enabled, toggle between Enable/Disable.
Page 163
6100-Gfast Multifunction Copper Tester Operation Manual 16.3 Test Setup Test Duration allows you to set the duration of the VoIP test, in seconds. The Test Setup tab allows you to configure profile Communication Channel is the values for the optional sub-tests within the 3 types of parameter based on either UDP or test applications.
Page 164
Controller Setup The Controller is the local VoIP connection for your 6100-Gfast. The Controller Setup Info page allows you to set the following VoIP parameters for your unit: User Name allows you to enter alphanumeric characters in this field using the editor screen to create a name.
Page 165
Bridged (DHCP) over xDSL and Ethernet interfaces enabling the uses same parameters as DHCP mode. 6100-Gfast to join and leave multicast IPTV streams. To configure test setup values: The following parameters can be configured from the Test Setup tab: 1.
Page 166
6100-Gfast Multifunction Network Analyzer Operation Manual Auto IPTV Test Setup page, it will 16.4 Channel List Setup also be removed from those lists. Accept replaces the edited value for The Channel List Setup page in the IPTV test setup the current highlighted entry.
Page 167
6100-Gfast Multifunction Copper Tester Operation Manual IPTV Channel Analysis - Enable to add Ping Test Setup channels for analysis. If disabled, channel analysis in auto test is not performed. Stream Time defines the length of time, from 1 to 60 s, to keep the channel stream(s) for analysis.
Page 168
6100-Gfast Multifunction Network Analyzer Operation Manual 5. If you make any changes to the parameter FTP Test Setup values, press the on-screen function keys to save or cancel your input. Enter IPv6 Address The FTP test verifies the file transfer speed of the file download and upload.
Page 169
6100-Gfast Multifunction Copper Tester Operation Manual 5. If you make any changes to the parameter values, press the on-screen function keys to 3. Press on a value to open a list box of save or cancel your input. options or the alphanumeric editor screen and use the navigation keys to scroll through.
Page 170
6100-Gfast Multifunction Network Analyzer Operation Manual 3. Press on a value to open a list box of options or the alphanumeric editor screen and use the navigation keys to scroll through. 4. Press to confirm the value. Traceroute Test Setup...
Page 171
6100-Gfast Multifunction Copper Tester Operation Manual 5. If you make any changes to the parameter Setup values, press the on-screen function keys to save or cancel your input. Web Browser Test Setup The Setup function displays the following sub-menu: ...
Page 172
See Cable Connections on page 8 for more information on connecting to your unit. If your modem is 6100-Gfast, then DSLAM entry is visible and allows you to choose the following: Annex B The General tab allows you to configure the unit with specific measurement values.
Page 173
6100-Gfast Multifunction Copper Tester Operation Manual 2. Press the left/right arrow keys to view and 3. Press on a value to open a list box of select the options. options or the alphanumeric editor screen and use the navigation keys to scroll through.
Page 174
6100-Gfast Multifunction Network Analyzer Operation Manual File Name Change Order The File Name tab sets up the standard configuration for automatically naming a result file. You can only Enable/Disable the entries. All enabled entries are considered for file name generation.
Page 175
6100-Gfast Multifunction Copper Tester Operation Manual VoIP Phone Book Phone Book Details The Phone Book menu presents a selection of functions which allow you to manage phone numbers relevant to performing VoIP tests. The Phone Book Details page allows you to view, add, and edit VoIP Phone Book entries.
Page 176
6100-Gfast Multifunction Network Analyzer Operation Manual To setup the Phone Book details: 1. Press the up/down arrow keys to select the desired entry. 2. Use the on-screen function buttons to create or edit the details. Enter SIP Address The Storage Location lists the load...
Page 177
6100-Gfast Multifunction Copper Tester Operation Manual 6100 internal memory Save Phone Book The Save Phone Book page allows you to save or export a phone book. Entry displays the number of the phone book(s). File Name lists the phone book file name(s).
Page 178
Line Status parameters. reaches Show Time. In the case of bonding, Simply connect to the line, turn on the 6100-Gfast, and both lines must reach Show Time before the select a test to run. Results obtained include upstream counter starts.
Page 179
6100-Gfast Multifunction Copper Tester Operation Manual If the Operation Mode is bonded, the actual bit rate is a summary of both DSL lines. 17.2 Ethernet Connection Summary WAN Access specifies the encapsulation method used by the network and consists of...
Page 180
6100-Gfast Multifunction Network Analyzer Operation Manual Access Mode in Connection Setup, because 17.4 LAN Status there are 2 assigned IPv6 addresses: the The LAN Status tab allows you to view the pass/fail global one (WAN) and the local one (Link- status and parameters related to the LAN (local area Local).
Page 181
6100-Gfast Multifunction Copper Tester Operation Manual 17.5 VoIP Call Avg. MOS - average Mean Opinion Score, which provides a relative measurement of VoIP The VoIP Call feature allows you to place and receive call quality. VoIP calls while displaying phone numbers, call status, ...
Page 182
6100-Gfast Multifunction Network Analyzer Operation Manual Touch-Tone Keypad The Phone Book page allows you to enter a new address, access Recently Dialed numbers, or Select The Touch-Tone Keypad allows you to enter a DTMF From Phone Book. number to dial a VoIP Call. The page contains ...
Page 183
6100-Gfast Multifunction Copper Tester Operation Manual Recently Dialed The Select From Phone Book page contains a selection of entries from the Phone Book, to make a The Recently Dialed page contains a list of previously VoIP Call. dialed SIP entries which you can select to make your call.
Page 184
6100-Gfast Multifunction Network Analyzer Operation Manual Jitter displays the average, current, and To set threshold values: maximum variation (in ms) in the packet transit delay of received VoIP packets. 1. Press the up/down arrow keys to highlight the desired parameter.
Page 185
6100-Gfast Multifunction Copper Tester Operation Manual Join Leave To view the Channel Analysis, press from the IPTV Summary tab. The Join Leave tab displays a list of IPTV channels from the alias table, their activity (measured Zap time), and pass/fail status. Upon successful WAN Channel Analysis connection, the Join/Leave Channel lists are shown.
Page 186
6100-Gfast Multifunction Network Analyzer Operation Manual Power Save State refers to the power-save DSL Parameter Details mode of the DPU (distribution point unit) and displays one of three states: L0 (power full on), L1 (low power), or L2 (idle).
Page 187
6100-Gfast Multifunction Copper Tester Operation Manual FEC is the Reed Solomon forward Bitswap specifies the status of the bit error correction. swapping mechanism - Active or Not Active - swapping bits from tone m to tone n to prevent Errored Seconds is the number of modem retraining.
Page 188
6100-Gfast Multifunction Network Analyzer Operation Manual Performance Counters - Local/Remote 17.6 Band Information G.INP RTX_TX is the number of frames retransmitted by the transmitter. The Local number is what is The Band Information tab allows you to view a list of...
Page 189
6100-Gfast Multifunction Copper Tester Operation Manual Signal Attenuation (ADSL, G.fast) is Recent based on the most recent the current reduction of signal strength refresh values. Press the Loop Diagnostics tab to refresh the ALN and is measured periodically when the line is connected.
Page 190
6100-Gfast Multifunction Network Analyzer Operation Manual Ping Test FTP Test The Ping Test tab allows you to view the Pass/Fail The FTP Test tab displays the FTP download and summary status of either a Ping Address or Ping upload results configured in the connection setup, Gateway.
Page 191
6100-Gfast Multifunction Copper Tester Operation Manual Speedtest by Ookla can be downloaded by the unit. The page displays the HTTP Download Status/speed and results; and a pass/fail summary status of whether or not the test was completed successfully or not. Except for Auto...
Page 192
Web Browser key is disabled. The 6100-Gfast web browser is intended as a tool to Forward takes you to the next web view web pages and confirm internet connections. It page (if available). If no web page was...
Page 193
6100-Gfast Multifunction Copper Tester Operation Manual To edit the web address: GO saves the bookmarks and starts the web connection using the address in URL box. 1. Press to highlight the URL box. Press to exit from the Bookmarks page avoiding 2.
Page 194
Job ID allows you to create/edit a file during or after performing a DSL/IP test, with the unique identifier for the task. 6100-Gfast. Each Auto Test, Manual, and Ethernet Customer Name is the name of the test includes an Upload/Save Result tab to do so.
Page 195
6100-Gfast Multifunction Copper Tester Operation Manual Select Result File Reports include: Product/General Information including status. Pass Fail Identification Profile/Results Summary Blank entries for your Signature and the Date. Report File Name allows you to preview and edit the result file name. The proposed file...
Page 196
18.2 Managing Results You can view, Upload, Export, and Delete any of your 2. Press to display the list or select the saved results with the 6100-Gfast by highlighting the value. Result Manager icon from the DSL Main pane and pressing...
Page 197
6100-Gfast Multifunction Copper Tester Operation Manual 3. Press the down arrow key to highlight the list The Export page allows you to select a File Name or All files previously saved and export the results in a box and press to open the list.
Page 198
6100-Gfast Multifunction Network Analyzer Operation Manual Delete The Delete page allows you to delete a selected File Name or All selected result files previously saved in the 6100 internal memory only. Storage Location is the 6100 internal memory. ...
Page 199
6100-Gfast is: 2 years. 19.1 General Maintenance The 6100-Gfast has been designed to be a rugged and For newly delivered units, Radiodetection has lightweight piece of test equipment. The 6100-Gfast determined that the storage of this product for up to six...
Page 200
2. Disconnect any unused USB or SD Replacing the Battery accessories. 3. Quit any running tests when the 6100-Gfast is not in use. WARNING: Only use a manufacturer-supplied battery. Batteries from other suppliers could result in 4.
Page 201
6100-Gfast Multifunction Copper Tester Operation Manual 19.4 Recycling and Disposal Disposal This symbol on the product, accessories or literature indicates that the product and its electronic accessories (for example, charger, headset and USB cable) must not be treated as domestic waste, but must be disposed of professionally.
Page 202
6100-Gfast Multifunction Network Analyzer Operation Manual Troubleshooting 20.1 Solving Common Problems The table below presents common problems and their solution. Problem Possible cause Solution The unit does not turn on You did not press long Press for a few seconds...
Page 205
(the “effective date”). If you do not accept this Agreement, you should not order, install, download, nor use the software and contact Radiodetection for a refund, if applicable.
Page 206
21.3 LICENSE GRANT 21.3.1 License Grant. Subject to the terms and conditions of this Agreement, Radiodetection grants to Customer a personal, non-sublicensable, non-transferable and non-exclusive license to have Users install and use the Software in accordance with the Documentation and solely within Customer's own personal or business operations, as the case may be.
Page 207
Radiodetection may establish in its sole discretion. 21.5.3 Radiodetection reserves the right, in any way and without notice, to revise, not to revise, update or modify the Software, or the information upon which the Software was based. Except as otherwise expressly set...
Page 208
Software. 21.6 COOKIE AND PRIVACY POLICY If the use of the Software allows connection to a Radiodetection Server and/or Third Party’s Server, Customer and Users consent to Radiodetection’s collection, use and disclosure of information associated with the Software solely in accordance with Radiodetection’s and/or Third Party’s Cookie and Privacy Policy, as it may be updated...
Page 209
21.10 LIMITED WARRANTY AND EXCLUSIVE REMEDY Radiodetection warrants that for a period of sixty (60) days from the date of delivery ("Warranty Period"), that the Software will operate and perform materially in conformance with the Documentation. If a breach of the warranty...
Page 210
21.13.4 Upon termination of this Agreement, Customer shall return the Software and the Documentation, including all copies and, if requested, certify in writing to Radiodetection the return. Customer is bound by all obligations incurred prior to the termination; however, all of Radiodetection's obligations will automatically terminate upon termination.
Page 211
END OF TERMS AND CONDITIONS CONTACT INFORMATION: If you have any questions about this Agreement, please direct all correspondence to: Radiodetection Ltd. Western Drive, Bristol BS14 0AF, UK. Legal notice shall be sent to the attention of the Radiodetection Legal representative.
Page 212
Information provided by Radiodetection is believed to be accurate and reliable. However, no responsibility is assumed by Radiodetection for its use nor for any infringements of patents or other rights of third parties that may result from its use. No license is granted by implication or otherwise under any patent rights of Radiodetection or third parties.
Page 213
United States and/or other countries. Due to a policy of continued development, we reserve the right to alter or amend any published specification without notice. This document may not be copied, reproduced, transmitted, modified or used, in whole or in part, without the prior written consent of Radiodetection Ltd.
Need help?
Do you have a question about the 6100-Gfast and is the answer not in the manual?
Questions and answers