1-2. Dimensional Data
(A) Indoor Units: Ceiling Type S-100PT2E5B, S-125PT2E5B, S-140PT2E5B
Detailed view of intaking
outside air duct connection port
9
Air intake
1 Drain port VP20 (inside diameter ø26mm, drain hose supplied)
2 Left drain position
3 Refrigerant liquid tubing (ø9.52mm, flare connection)
4 Refrigerant gas tubing (ø15.88mm, flare connection)
5 Cover of rear tubing hole
6 Tubing hole on wall surface (ø100mm)
7 Upper side tubing port
8 Right side drain hose outlet port (cutout)
9 Left side drain hose outlet port (cutout)
10 Left-rear side drain hose outlet port (cutout)
11 Power inlet port
12 Remote control wiring and inter-unit wiring inlet port
13 Wireless remote controller receiver installation location
14 Outside air intake duct connection port (ø100mm, cutout)
<Filter size>
(736 x 250 x 16) x 2 pcs.
Air
Over
discharge
250
Service space
2
90
(Left drain position)
(Closed with rubber stopper
at time of shipment.)
123
7
1541
(Suspension bolt pitch)
1584
1590
4
3
Hole position of indoor unit rear-side
(Figure shows view from front)
120
90
Tubing hole position on wall surface
(Figure shows view from front)
1-2-5
unit :mm
61
Distance of each exposed
bolt must be of equal length
within 50mm.
Suspension
bolt
Unit
Ceiling
surface
Bracket
690
Over
80
250
Service space
13
86 (Gas tubing)
70 (Liquid tubing)
90 (Right drain position)
97
123
70
5
14
10
90
11 12
96
6
1 8
216
186
86