Dimplex XLF50 Owner's Manual page 9

Hide thumbs Also See for XLF50:
Table of Contents

Advertisement

Available languages

Available languages

Fireplace Installation
Figure 4
required.
6. Drive four supplied mounting
screws through the four mount-
ing holes located on the inside
surface of the fireplace chassis,
into wall studs (Figure 4).
120V Installation - Direct Wire
!
NOTE: The unit is designed
to be hardwired to a power
source and should not have
a cord installed to allow the
unit to be plugged into a wall
receptacle.
Use two conductor, non-metallic
sheath cable with ground wire
(3 wires total) for the incoming
power supply.
CAUTION: Use the appropri-
ate wire to meet local and
national electrical codes for
rated power consumption.
Mounting Holes
• Cut the wire to an appropriate
length.
• Connect the L wire from the
unit to the live wire from the
power supply with a wire nut.
• Connect the N wire from the
unit to the neutral wire from
the power supply with a wire
nut.
• Connect the G wire from the
unit to the ground wire from
the power supply with a wire
nut or attach the ground-
ing wire to the cover with the
provided grounding screw, by
placing the wire in-between
screw and lock washer and
tighten (Figure 3).
• Ensure that all wires are se-
cure and do not protrude past
the flame panel, so as not to
be visible after final assembly.
Flame
Panel
9