Graco BULLDOG HYDRA-CAT E Series Instructions-Parts List Manual page 19

Proportioning pumps 2500 psi (17 mpa, 170 bar) 1:1 mix ratio, 1–1/4:1 mix ratio, 1–1/2:1 mix ratio, 2:1 mix ratio, 3:1 mix ratio, 4:1 mix ratio, 2–1/2:1 mix ratio
Table of Contents

Advertisement

Pump operates but Part B output
pressure drops during upstroke.*
Pump operates but part B output pres-
sure drops during downstroke.*
Pump operates but part B output pres-
sure drops during both strokes.*
Fluid leaks around fluid pump packing
nut.
Relief valve opens too soon or won't
close.
* Fluid ratio will be wrong.
** Purge all air out of the system before proportioning the fluids.
Troubleshooting Chart
Dirty, worn or damaged part B pump
piston valve.
Worn or damaged part B pump piston
packings.
Dirty, worn or damaged part B pump
intake valve.
Fluid not filling cylinder on upstroke,
"diving" on top of change–over.
Dirty, worn or damaged part B pump
intake valve.
Fluid supply low.**
Loose packing nut or worn throat
packings.
Relief valve is damaged.
Clean, service – see instruction
manual 307944.
Replace.
Clean, service – see instruction
manual 307944.
Increase pressure on feed
pump. Check inlet filter screen.
Check foot valve.
Clean, service – see instruction
manual 307944.
Refill or change container.
Tighten, replace.
Service – see instruction manual
308547.
307132
19