Addresses 00 to 15 store the Primary Phone Number. Enter 'F' to represent the end of the number.
Primary Comm Format: Enter 0 - F.
16
Primary Account Code: Valid keys are 0-F.
17
18
19
20
Primary 24-Hour Test Time. Enter military time (i.e. 1400 for 2 PM).
21
22
23
24
Primary Number Test Time Interval. Enter '0' for 24-hour; '1' - 12-hour.
25
26
27
28
29
Addresses 26-41 store the Secondary Phone Number. Enter 'F' to represent the end of the number.
Secondary Comm Format: Enter 0-F.
42
Secondary Account Code: Valid keys are 0-F.
43
44
45
46
Secondary 24-Hour Test Time. Enter military time (i.e. 1400 for 2 PM) .
47
48
49
50
Secondary Number Test Time Interval. Enter '0' for 24-hour; '1' - 12-hour.
51
Start Monitoring Address. Valid entries are 01 through 32.
52
53
End Monitoring Address. Valid entries are 01 through 32.
54
55
ADT-UDACT Communication Selection. Enter '0' to disable ADT-UDACT communication; '1' for zone
56
reporting receive only communication; '2' for zone reporting receive/transmit communication; '3' for point
reporting receive only; or '4' for point reporting receive/transmit.
Backup Reporting. Enter '0' to have secondary phone number act as backup only; '1' to have secondary
57
phone number receive all reports and messages along with primary phone number.
Touchtone/Rotary Select. Enter '0' for touchtone dialing; '1' for rotary dialing.
58
Make/Break Ratio. If rotary dialing is selected in Address 58; Enter '0' for a 67/73 make/break ratio; '1'
59
for a 62/38 make/break ratio.
Leave default of 0.
60
Leave default of 0.
61
AC Loss Reporting Delay. Enter '0' for no time delay after AC loss; '1' for 6 hour delay; '2' for 7 hour
62
delay; '3' for 8 hour delay; '4' for 9 hour delay; '5' for 10 hour delay; '6' for 11 hour delay; '7' for 15 hour
delay; '8' for 16 hour delay; '9' for 17 hour delay; 'A' for 18 hour delay; 'B' for 19 hour delay; 'C' for 20
hour delay; 'D' for 21 hour delay; 'E' for 22 hour delay; or 'F' for 23 hour delay.
Host Panel ID. Enter '7' for Unimode 2020/1010 and ADT-MNNA; '8' for Unimode 300/400; all other
63
entries are invalid.
Loop Number. Factory set to '00'. Valid entries are 00 through 97
64
65
Device/Zone Number for General Reports. Factory set to '000'. Valid entries are 000
66
67
68
through 999.
7.0 Programming Reference Sheets
--- To enter Programming, press Mode: 7 7 6 4, Enter
04
05
06
07
08
30
31
32
33
34
Document 50934
09
10
11
12
35
36
37
38
Rev B
5/15/00
PN 50934:B
13
14
15
39
40
41
43