Programming Reference Sheets - ADT -UDACT Product Information

Adt digital alarm communicator transmitter installation operation manual
Table of Contents

Advertisement

00
01
02
03
Addresses 00 to 15 store the Primary Phone Number. Enter 'F' to represent the end of the number.
Primary Comm Format: Enter 0 - F.
16
Primary Account Code: Valid keys are 0-F.
17
18
19
20
Primary 24-Hour Test Time. Enter military time (i.e. 1400 for 2 PM).
21
22
23
24
Primary Number Test Time Interval. Enter '0' for 24-hour; '1' - 12-hour.
25
26
27
28
29
Addresses 26-41 store the Secondary Phone Number. Enter 'F' to represent the end of the number.
Secondary Comm Format: Enter 0-F.
42
Secondary Account Code: Valid keys are 0-F.
43
44
45
46
Secondary 24-Hour Test Time. Enter military time (i.e. 1400 for 2 PM) .
47
48
49
50
Secondary Number Test Time Interval. Enter '0' for 24-hour; '1' - 12-hour.
51
Start Monitoring Address. Valid entries are 01 through 32.
52
53
End Monitoring Address. Valid entries are 01 through 32.
54
55
ADT-UDACT Communication Selection. Enter '0' to disable ADT-UDACT communication; '1' for zone
56
reporting receive only communication; '2' for zone reporting receive/transmit communication; '3' for point
reporting receive only; or '4' for point reporting receive/transmit.
Backup Reporting. Enter '0' to have secondary phone number act as backup only; '1' to have secondary
57
phone number receive all reports and messages along with primary phone number.
Touchtone/Rotary Select. Enter '0' for touchtone dialing; '1' for rotary dialing.
58
Make/Break Ratio. If rotary dialing is selected in Address 58; Enter '0' for a 67/73 make/break ratio; '1'
59
for a 62/38 make/break ratio.
Leave default of 0.
60
Leave default of 0.
61
AC Loss Reporting Delay. Enter '0' for no time delay after AC loss; '1' for 6 hour delay; '2' for 7 hour
62
delay; '3' for 8 hour delay; '4' for 9 hour delay; '5' for 10 hour delay; '6' for 11 hour delay; '7' for 15 hour
delay; '8' for 16 hour delay; '9' for 17 hour delay; 'A' for 18 hour delay; 'B' for 19 hour delay; 'C' for 20
hour delay; 'D' for 21 hour delay; 'E' for 22 hour delay; or 'F' for 23 hour delay.
Host Panel ID. Enter '7' for Unimode 2020/1010 and ADT-MNNA; '8' for Unimode 300/400; all other
63
entries are invalid.
Loop Number. Factory set to '00'. Valid entries are 00 through 97
64
65
Device/Zone Number for General Reports. Factory set to '000'. Valid entries are 000
66
67
68
through 999.

7.0 Programming Reference Sheets

--- To enter Programming, press Mode: 7 7 6 4, Enter
04
05
06
07
08
30
31
32
33
34
Document 50934
09
10
11
12
35
36
37
38
Rev B
5/15/00
PN 50934:B
13
14
15
39
40
41
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents