Secondary Number Communication Format (42). Programming is the same as the
primary number's Comm Format at address 16. Default entry is 'A', 4+2 Standard.
When selecting the Format, note that Ademco Contact ID is the only format in the
ADT-UDACT which identifies the specific zone or point status to the Central Station.
All other formats report the number of zones or points that are active but do not identify
the specific zone or point. Choose one entry from the list below:
0: 4+1 Ademco Express Standard, DTMF, 1400/2300 ACK
1: 4+2 Ademco Express Standard, DTMF, 1400/2300 ACK
2: 3+1 Standard 1800 Hz Carrier, 2300 Hz ACK
3: Not Used
4: 3+1 Standard 1900 Hz Carrier, 1400 Hz ACK
5: Not Used
6: 4+1 Standard 1800 Hz Carrier, 2300 Hz ACK
7: Not Used
8: 4+1 Standard 1900 Hz Carrier, 1400 Hz ACK
9: Not Used
A: 4+2 Standard 1800 Hz Carrier, 2300 Hz ACK
B: Not Used
C: 4+2 Standard 1900 Hz Carrier, 1400 Hz ACK
D: Not Used
E: Ademco Contact ID
F: Not Used
Secondary Number Account Code (43-46) is programmed in addresses 43 - 46 in
the same manner as the primary phone number Account Code. Default entries are all
'0s'.
Secondary Number 24-Hour Test Time (47-50) is programmed in addresses 47-
50 in the same manner as the primary number 24-Hour Test Time. Default is 00:00
(12:00 midnight).
Secondary Number 24/12 Hour Test Time (51) The test message sent to the
Secondary phone number may be sent every 12 or 24 hours. If the message is to be
sent every 24 hours, leave the factory default entry of zero. If a 12 hour test report
time is needed, enter 1=12 hours.
Use the Start and End Monitoring Address programming locations to set the
reporting range of the ADT-UDACT.
Start Monitoring Address (52-53) is programmed to indicate the first group of
zones or points to be monitored and reported to the Central Station. Valid entries are
'11 through 19' for the Unimode 300/400, and '01 through 32' for the Unimode 2020/
1010 and ADT-MNNA. The factory default setting is '01'. See Table 3-1.
End Monitoring Address (54-55) is programmed to indicate the last group of zones
or points to be monitored and reported to the Central Station. Valid entries are '11
through 19' for the Unimode 300/400, and '01 through 32' for the Unimode 2020/
1010 and ADT-MNNA. Factory default setting is '02'.