Download Print this page

Safety Regulations - Pepperl+Fuchs Ecom Pad-Ex 01 HR DZ2 User Manual

Intrinsically safe tablet pc
Hide thumbs Also See for Ecom Pad-Ex 01 HR DZ2:

Advertisement

Appendix
Ex - Data
1.
ATEX
EC type approval test certificate no.
Ex-marking
Ambient temperature
2.
IECEx
IECEx Certificate of Conformity no.
Ex-marking
Ambient temperature

Safety regulations

Use of this unit assumes that the user observes the conventional safety
regulations and has read the certificate in order to eliminate faulty operation
of the unit.
• Do not open the device inside the Ex-area
• For safe use it is required that the device is fitted with protection screen
and cover for docking connector (see picture page 49).
• Do not open the I/O port cover inside the Ex-area.
• The batteries may only be exchanged outside the Ex-area
• The battery may only be charged outside the Ex-area
• Before entering the Ex-area the I/O port cover must be closed
• The device must be protected against strong impacts
• The device must be protected against high electrostatic charge generating
processes
• In hazardous areas including IIC gases it is only allowed to clean the unit
and applied accessory with damp cloth
• Only those accessories approved by ecom instruments GmbH may be used
EPS 16 ATEX 1 163 X
† II 3G Ex ic IIC T4 Gc IP64
† II 3D Ex ic IIIB T135°C Dc IP64
-10 °C ≤ Ta ≤ +55 °C
IECEx EPS 16.0072X
Ex ic IIC T4 Gc IP64
Ex ic IIIB T135°C Dc IP64
-10 °C ≤ Ta ≤ +55 °C