Spellman XRM Series Instruction Manual

Spellman XRM Series Instruction Manual

High voltage power supply

Advertisement

Quick Links

High Voltage Power Supply
SPELLMAN
HIGH VOLTAGE ELECTRONICS
CORPORATION
475 Wireless Blvd.
Hauppauge, New York, 11788
+1(631) 630-3000*FAX: +1(631) 435-1620*
E-mail:
sales@spellmanhv.com
Website: www.spellmanhv.com
XRM MANUAL
XRM SERIES
MODEL :
SERIAL# :
DATE :
R
118033-001 Rev F

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XRM Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Spellman XRM Series

  • Page 1 XRM SERIES High Voltage Power Supply MODEL : SERIAL# : DATE : SPELLMAN HIGH VOLTAGE ELECTRONICS CORPORATION 475 Wireless Blvd. Hauppauge, New York, 11788 +1(631) 630-3000*FAX: +1(631) 435-1620* E-mail: sales@spellmanhv.com Website: www.spellmanhv.com XRM MANUAL 118033-001 Rev F...
  • Page 2 CAUTION notes in the text indicate procedures to be followed to avoid possible damage to equipment. Copyright © 2000, Spellman High Voltage Electronics Corporation. All Rights Reserved. This information contained in this publication is derived in part from proprietary and patent data. This information has...
  • Page 3 WICHTIGE SICHERHEITSHINWEISE SICHERHEIT DIESES HOCHSPANNUNGSNETZTEIL ERZEUGT LEBENSGEFÄHRLICHE HOCHSPANNUNG. SEIN SIE SEHR VORSICHTIG BEI DER ARBEIT MIT DIESEM GERÄT. Das Hochspannungsnetzteil muß immer geerdet sein. Berühren Sie die Stecker des Netzteiles nur, wenn das Gerät ausgeschaltet ist und die elektrischen Kapazitäten des Netzteiles und der angeschlossenen Last entladen sind. Die internen Kapazitäten des Hochspannungsnetzteiles benötigen ca.
  • Page 4 PRECAUTIONS IMPORTANTES POUR VOTRE SECURITE CONSIGNES DE SÉCURITÉ ETTE ALIMENTATION GÉNÈRE DES TENSIONS QUI SONT DANGEUREUSES ET PEUVENT ÊTRE FATALES OYEZ EXTRÊMENT VIGILANTS LORSQUE VOUS UTILISEZ CET ÉQUIPEMENT Les alimentations haute tension doivent toujours être mises à la masse. Ne touchez pas les connectiques sans que l’équipement soit éteint et que la capacité à la fois de la charge et de l’alimentation soient déchargées.
  • Page 5 IMPORTANTI PRECAUZIONI DI SICUREZZA SICUREZZA QUESTO ALIMENTATORE GENERA TENSIONI CHE SONO PERICOLOSE E POTREBBERO ESSERE MORTALI. PONI ESTREMA CAUTELA QUANDO OPERI CON QUESO APPARECCHIO. Gli alimentatori ad alta tensione devono sempre essere collegati ad un impianto di terra. Non toccare le connessioni a meno che l’apparecchio sia stato spento e la capacità interna del carico e dell’alimentatore stesso siano scariche.
  • Page 6 SICHERHEIT DIESES HOCHSPANNUNGSNETZTEIL ERZEUGT LABENSGEFÄHRLICHE HOCHSPANNUNG. SEIEN SIE SEHR VORSICHTIG BEI DER ARBEIT MIT DIESEM GERÄT Das Hochspannungsnetzteil muB inner geerdet sein. Berühren Sei die Stecker des Netzteiles nur wenn das Gerät ausgeschaltet ist und die elektrischen Kapazitäten des Netzteiles und der angeschlossenen Last entladen sind. Die internen Kapazitäten des Hochspannungsnetzteiles benötigen ca.
  • Page 7: Table Of Contents

    Table of Contents PAGE 1. INTRODUCTION Description of The XRM Series ................1 XRM Specifications.....................1 Standard Features....................2 1.3.1 Remote Operating Features ..............2 Options.........................2 Interpreting the Model Number ................2 2. INSPECTION & INSTALLATION Initial Inspection ....................3 Mechanical Installation..................3 3. OPERATING INSTRUCTIONS Operation ......................5 Standard Features....................6...
  • Page 8 8. FACTORY SERVICE Warranty Repairs ....................16 Factory Service Procedures .................16 Ordering Options and Modifications ..............16 Shipping Instructions ...................16 APPENDIX Specification Controls (Custom Models Only) LIST OF FIGURES Figure 2.1 Dimensions XRM ..................4 Figure 3.1 Typical Operating Setup XRM ..............7 Figure 3.2 DC Input &...
  • Page 9: Introduction

    Ripple: 0.25% p-p of maximum output voltage. technology.  Filament: 3.5A, 5.5V The XRM series is specifically designed for X-ray tube application where the high voltage is a positive polarity,  Stability: 0.05% per 8 hours after ½ hour warm up.
  • Page 10: Standard Features

    1.3 Standard Features 1.4 Options The XRM series incorporates several standard features CODE DISCRIPTION designed to optimize user satisfaction and safety. • AC Filament MA/FILAMENT CURRENT RAMP • SS(X) Non-Standard Slow Start CIRCUITS: This feature provides for a gradual rise for kV, mA and filament current.
  • Page 11: Inspection & Installation

    2.2 Mechanical Installation Inspect the package exterior for evidence of damage due to handling in transit. Notify the Units in the XRM series have front panel holes carrier and Spellman immediately if damage is for standard EIA rack mounting. The rack must evident.
  • Page 12: Figure 2.1 Dimensions Xrm

    2.563 [65.1] DANGER HIGH 1.154 [29.3] VOLTAGE INTLK mA MON 2.126 [54.0] kV MON MON RTN BIAS FIL RTN DANGER +24V DANGER 2.047 [52.0] kV ADJ 6.300 [160.0] BIAS ADJ FIL LIM WARNING mA ADJ PWR ON CONTROL M4 x 0.7 6.496 [165.0] 1.752 [44.5] BLIND INSERTS...
  • Page 13: Operating Instructions

    BEVOR SIE DAS HOCHSPANNUNGSNETZEIL AN DIE NOTE: The XRM series is equipped with a slow start STROMVERSORGUNG ANSCHLIESSEN, circuit that ramps the output up to its maximum setting in approximately 4 seconds after the INTERLOCK is MÜSSEN FOLGENDE PUNKTE GEPRÜFT...
  • Page 14: Standard Features

    If possible, analog programming and monitoring signals should be isolated via analog isolation amplifiers. WARNUNG Spellman application engineers are available to assist in interface circuitry design. All interface cables should be Nach drm Ausschalten des Gerätes die Last erst properly shielded.
  • Page 15: Figure 3.1 Typical Operating Setup Xrm

    DANGER HIGH VOLTAGE INTLK mA MON kV MON ANODE MON RTN BIAS X-RAY TUBE FIL RTN DANGER FILAMENT +24V FILAMENT MUST BE GROUNDED DANGER kV ADJ BIAS ADJ FIL LIM WARNING mA ADJ PWR ON CONTROL HIGH VOLTAGE ELECTRONICS CORP HAUPPAUGE, NY 11788 Figure 3.1 Typical Operating Setup XRM XRM MANUAL...
  • Page 16: Figure 3.2 Dc Input & Filament Connections

    Table 3.2 DC Input & Filament Connections XRM MANUAL 118032-001 REV G...
  • Page 17: Figure 3.3 Monitors & Interlock Connections

    Figure 3.3 Monitors & Interlock Connections XRM MANUAL 118032-001 REV G...
  • Page 18: Figure 3.4 Local/Remote Control

    Figure 3.4 Local/Remote Control XRM MANUAL 118032-001 REV G...
  • Page 19: Principles Of Operation

    Department. approach or touch any internal or external circuits or components that are connected or *Due to the many variations within the XRM series, have been connected to the power supply. Be drawing numbers may differ from unit to unit.
  • Page 20: High Voltage Transformer

    The majority of control circuits for power supply controls Due to the many variations of models and options are located on the CONTROL/POWER PWB. provided in the XRM series, details of actual circuits used may differ slightly from above descriptions. Consult +15VDC, -15VDC, and +10VDC is generated on the Spellman’s...
  • Page 21: Options

    5.4 Non-Standard Slow Start instruction manual. SS(x) Spellman welcomes the opportunity to tailor units to fit The non-standard slow start option allows the gradual rise your requirements or to develop new products for your time of the output voltage to be different from the applications.
  • Page 22: Maintenance

    Copies can be obtained from the Spellman Customer Service Department. Test equipment, WARNUNG including an oscilloscope, a high impedance voltmeter, and a high voltage divider such as the Spellman HVD- DIESES HOCHSPANNUNGSNETZTEIL ERZEUGT 100 or HVD-200, is needed for performance tests. All LEBENSGEFÄHRLICHE HOCHSPANNUNG! test components must be rated for operating voltage.
  • Page 23: Replacement Parts

    Spellman Customer Service Department for parts lists for specific models. Each Spellman power supply has an identification label on the rear of the chassis that bears its model and serial Spellman provides parts and subassemblies for its high number.
  • Page 24: Factory Service

    Follow received at the Spellman Repair Center. In the event that the return procedures described in Section 8.2. repair work is extensive, Spellman will call to seek customer shall pay for shipping to and from Spellman.
  • Page 25 To obtain information on Spellman’s product warranty please visit our website at: http://www.spellmanhv.com/en/About/Warranty.aspx...

Table of Contents