Cleaning The Screen Element; Removing/Fitting A Screen Element; Decalcifying The Screen Elements; Removing/Fitting The Filter Drum - Oase ProfiClear Premium Compact-L EGC Operating Instructions Manual

Table of Contents

Advertisement

Downloaded from www.watergardeningdirect.com
- EN -
8.5

Cleaning the screen element

8.5.1

Removing/fitting a screen element

How to proceed:
 U
Removing
1. Turn the filter drum manually until the screen element is located opposite the drum motor. Undo the
locking mechanism (turn through 180°).
2. Lower the screen element completely into the filter drum.
3. Remove the screen element from the filter drum.
Fitting
4. Lower the screen element completely into the filter drum.
5. Turn the screen element and push the two hinges onto the support of the filter drum.
6. Use the cross element to pull the screen element up.
7. Close the locking mechanism (turn through 180°).
8.5.2

Decalcifying the screen elements

The error messages Er33, Er55 or an excessive rise in the frequency of cleaning cycles (counter) indicate
that there are limescale deposits on the screen elements. (→ Reading out the number of cleaning cycles)
Oase recommends that you descale the unit every two to three months as a preventative measure if the
water is very hard.
► Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
How to proceed:
1. Remove a screen element. (→ Removing/fitting a screen element)
2. Descale the screen element using a descaler (follow the manufacturer's instructions).
– Do not remove the rubber seal of the screen element.
3. Scrub the screen element with a soft brush under running water and rinse well.
4. Refit the screen element.
8.6

Removing/fitting the filter drum

Remove a screen element to allow work to be carried out inside the filter drum. (→ Removing/fitting a
screen element)
Removing
How to proceed:
 V
1. Pull the rinsing device out of the fastening clips and separating plate.
2. Undo and remove both Allen screws (width across flats 5), pull the drum motor out of the hole in the
separating plate and remove.
– Do not allow the drum motor to hang from the connection cable.
3. Undo the hose clip fastening the dirt channel.
4. Pull the dirt channel from the socket of the dirty water outlet and place it in the filter drum.
5. Open the cotter pin and pull it out.
6. Pull out the drum shaft.
7. Pull the filter drum from the separating plate and lift it out of the container.
– Proceed carefully: The fastening clips on the container wall could damage the screen elements.