Table of Contents

Advertisement

Downloaded from www.watergardeningdirect.com
Profi Clear Premium
Compact L

Advertisement

Table of Contents
loading

Summary of Contents for Oase ProfiClear Premium Compact-L EGC

  • Page 1 Downloaded from www.watergardeningdirect.com Profi Clear Premium Compact L...
  • Page 2 Downloaded from www.watergardeningdirect.com -  - ProfiClear0126...
  • Page 3 Downloaded from www.watergardeningdirect.com -  - ProfiClear0125 ProfiClear0143 ProfiClear0142...
  • Page 4 Downloaded from www.watergardeningdirect.com -  - ProfiClear0127...
  • Page 5 Downloaded from www.watergardeningdirect.com -  - ProfiClear0128 ProfiClear0164...
  • Page 6 Downloaded from www.watergardeningdirect.com -  - ProfiClear0129 ProfiClear0130...
  • Page 7 Downloaded from www.watergardeningdirect.com -  - ProfiClear0131 ProfiClear0132 ProfiClear0040...
  • Page 8 Downloaded from www.watergardeningdirect.com -  - ProfiClear0133 FMR0031 EGC0003...
  • Page 9 Downloaded from www.watergardeningdirect.com -  - ProfiClear0134 BTC0031 ProfiClear0044 ProfiClear0136...
  • Page 10 Downloaded from www.watergardeningdirect.com -  - PrifiClear0135 ProfiClear0041 ProfiClear0137...
  • Page 11 Downloaded from www.watergardeningdirect.com -  - ProfiClear0138 ProfiClear0140 ProfiClear0141 ProfiClear0139...
  • Page 12 Downloaded from www.watergardeningdirect.com - EN - - EN - Translation of the original Operating Instructions W A R N I N G ► This unit can be used by children aged 8  and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved.
  • Page 13: Table Of Contents

    Downloaded from www.watergardeningdirect.com - EN - Table of Contents Information about this operating manual ..................48 1.1 Warnings used in these instructions ..................48 1.1.1 Cross-references used in these instructions ............... 48 Safety information ..........................49 2.1 Electrical connection ........................ 49 2.2 Danger for persons with pacemakers ..................
  • Page 14 Downloaded from www.watergardeningdirect.com - EN - 6.5.3 In: Time-dependent cleaning "Interval" ................. 66 6.5.4 E7: Pump status detection ..................... 67 6.6 Reading out the number of cleaning cycles ................67 6.6.1 Cleaning cycles in 24 hours ..................67 6.6.2 Total cleaning cycles ....................68 6.7 Loading default settings ......................
  • Page 15: Information About This Operating Manual

    - EN - Information about this operating manual Welcome to OASE Living Water. You made a good choice with the purchase of this product ProfiClear Premium Compact-L EGC. Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit.
  • Page 16: Safety Information

    Downloaded from www.watergardeningdirect.com - EN - Safety information Electrical connection ► Electrical installations must meet the national regulations and may only be carried out by a qualified electrician. ► A person is regarded as a qualified electrician if, due to his/her vocational education, knowledge and experience, he or she is capable of and authorised to judge and carry out the work commissioned to him/her.
  • Page 17: Product Description

    - EN - Product Description The OASE filter system ProfiClear Premium Compact includes the drum filter unit ProficClear Premium Compact and the ProfiClear Premium individual module. Depending on the module, the filter system can be operated as a pump fed or gravity fed system. An additional Moving Bed module can be connected to the gravity fed system.
  • Page 18: Unit Configuration

    Downloaded from www.watergardeningdirect.com - EN - Unit configuration  E Pump fed  F Gravity fed Description Container cover Signal box with level detection device (3) and temperature probe (7) • The signal box is connected to the control system (30, 32) Level detection device •...
  • Page 19: Function Description

    This product can communicate with the Easy Garden Control-System (EGC). EGC allows convenient control in the garden and pond via smartphone or tablet, and ensures maximum convenience and reliability. Information about EGC and the possibilities it offers can be found at www.oase- livingwater.com/egc-start.
  • Page 20: Installation And Connection

    Downloaded from www.watergardeningdirect.com - EN - Installation and connection C A U T I O N Risk of injury due to sharp-edged components. ► Proceed with caution during any work on the filter container to prevent injuries caused by sharp-edged components.
  • Page 21: Pump Fed System

    – If the water level goes below the max. water level by more than 20 mm, it is not possible to achieve optimum or fault-free operation. ► Install the OASE ProfiClear Guard refill system. The ProfiClear Guard refill system automatically supplies water to the pond if the water level goes below the specified water level.
  • Page 22: Connecting The Drum Filter

    Downloaded from www.watergardeningdirect.com - EN - Connecting the drum filter 4.3.1 Information regarding pipes ► Use suitable pipes. ► Do not use any right-angled bends. Bends with a maximum angle of 45° are very efficient. ► Glue plastic pipes to ensure a permanent and reliable joint or use socket joints with clips to stop them from coming apart.
  • Page 23: Fitting The Uvc Clarifier

    Downloaded from www.watergardeningdirect.com - EN - Gravity fed system  B, J The filter system has three inlets DN 110. If necessary, the connection set (19005) can be used to install a fourth inlet DN 110. In this case, the maximum flow rate of the filter system increases to 33000 l/h. ►...
  • Page 24: Connecting The Dirt Outlet

    Downloaded from www.watergardeningdirect.com - EN - 4.3.5 Connecting the dirt outlet The water in the container can be drained via the DN 75 dirt outlet with slide valve at the bottom of the container if required (for cleaning, repair, overwintering). ►...
  • Page 25: Connecting An Additional Egc Compatible Unit

    Downloaded from www.watergardeningdirect.com - EN - 4.4.3 Connecting an additional EGC compatible unit An additional EGC compatible unit can be connected to the EGC box. ► Ensure the correct connection. How to proceed:  N, O 1. Remove the protection cap from EGC-OUT on the EGC box and fit the plug connector of the EGCConnection Cable.
  • Page 26: Connecting An External Aerator Pump

    Downloaded from www.watergardeningdirect.com - EN - Connecting an external aerator pump ► Connect the aerator rod in the container to an external aerator pump. OASE recommends: Volume Hel-X biomedia Minimum air volume OASE recommendation 60 l 1200 l/h at 1.0 mWS...
  • Page 27: Pump Fed System

    Downloaded from www.watergardeningdirect.com - EN - During commissioning, Er88 is indicated in the display of the control system, ► for as long as the final water level is not reached in the filter container, ► when the pump status detection is not correctly set. If the filter system operates correctly, the system message will reset automatically.
  • Page 28: Setting The Level Detection Device

    Downloaded from www.watergardeningdirect.com - EN - 5.1.2 Setting the level detection device A rise in the water level during operation indicates that the system is contaminated. The level detection device signals possible soiling to the control system and the cleaning cycle is started. The water level in the filter system is independent of the water level in the pond.
  • Page 29: Setting The Level Detection Device

    Downloaded from www.watergardeningdirect.com - EN - Switching on the control system and additional units, checking the pipes 11. Switch on the control system and perform any necessary adjustments. (→ Operation) 12. Switch on the filter pump and UVC clarifier (if applicable). –...
  • Page 30: Setting The Filter Pump Status Detection

    Downloaded from www.watergardeningdirect.com - EN - 5.2.3 Setting the filter pump status detection Setting is only necessary in the following circumstances: ► The installation height of the filter container differs from the system-specific requirements. ► The admissible frictional resistances in the supply lines differ considerably from those specified. The filter pump status detection signals via the system message Er88 if the filter pump is operating correctly.
  • Page 31: Operation

    Downloaded from www.watergardeningdirect.com - EN - Operation Control system overview ProfiClear_0001 Display • for displaying the operating status • for displaying the menus and values for setting the drum filter • Pump status display • the current water temperature [°C] is displayed as standard On|Off button, Quit Error •...
  • Page 32: Operating Modes

    Downloaded from www.watergardeningdirect.com - EN - Operating modes Description Information Automatic mode: • The display indicates the water temperature as standard. • Operating mode for normal operation. • A cleaning cycle is automatically started if the level detection device signals an excessive deviation in the water level. •...
  • Page 33: Ec: Extended Cleaning Time "Extra Cleaning

    Downloaded from www.watergardeningdirect.com - EN - 6.5.2 EC: Extended cleaning time "Extra Cleaning" To prevent larger deposits from building up in the dirt channel or pipework, the unit performs a cleaning cycle with an extended cleaning time after every 20 cleaning cycles. This ensures that the pipework is flushed out at regular intervals.
  • Page 34: E7: Pump Status Detection

    Downloaded from www.watergardeningdirect.com - EN - 6.5.4 E7: Pump status detection The pump status detection signals via the system message Er88 if the pump is operating correctly. The status detection is activated in the default setting. Proceed as follows Information •...
  • Page 35: Total Cleaning Cycles

    Downloaded from www.watergardeningdirect.com - EN - 6.6.2 Total cleaning cycles How to proceed Information The sum of the automatic, manual and time-dependent cleaning cycles is Press for 5 s. saved. The 8-digit value is divided into four groups of two digits that appear in the display in succession.
  • Page 36: System Messages

    Downloaded from www.watergardeningdirect.com - EN - System messages The 4-digit system message is indicated in the display by two groups of two digits in succession. System message Functions that are still Possible cause Remedy Resetting the system available message Container cover raised Container cover raised Refit the container cover Automatic when the...
  • Page 37 • Clean edge of the drum/drum seal and grease edge of the Er44 Press key for 5 s (The control system jammed drum Only use original OASE grease (order number attempted to start up the 27872). motor three times - 5 times • Ensure that the rollers move smoothly per attempt) •...
  • Page 38: Remedy Of Faults

    Downloaded from www.watergardeningdirect.com - EN - Remedy of faults Malfunction Possible cause Remedy No flow of water Filter pump not switched on. Switch on the filter pump, connect the power plug. Supply to filter system or return to pond Clean the supply and/or return. blocked.
  • Page 39: Maintenance And Cleaning

    ► Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or impair the function of the unit. ► Recommended cleaning agent for removing stubborn limescale deposits: – Pump cleaning agent PumpClean from OASE. – Vinegar- and chlorine-free household cleaning agent. ► After cleaning, thoroughly rinse all parts in clean water.
  • Page 40: Regular Tasks

    Downloaded from www.watergardeningdirect.com - EN - Regular tasks The filter system is self-cleaning. Carry out the following work regularly to ensure the optimum cleaning capacity of the filter system. Regular checks ► Check the display of the control system for any system messages. (→ System messages) ►...
  • Page 41: Cleaning The Screen Element

    The error messages Er33, Er55 or an excessive rise in the frequency of cleaning cycles (counter) indicate that there are limescale deposits on the screen elements. (→ Reading out the number of cleaning cycles) Oase recommends that you descale the unit every two to three months as a preventative measure if the water is very hard.
  • Page 42: Cleaning The Rinsing Pump

    Downloaded from www.watergardeningdirect.com - EN - Fitting How to proceed:  V, W Before fitting the filter drum check that the drum seal is undamaged and correctly positioned. Lubricate the seal with the supplied grease. Replace the drum seal if damaged. 1.
  • Page 43: Storage/Overwintering

    ► Protect pipes and slide valves that are in contact with water from frost. Wear parts ► Capacitor of the rinsing pump – Do not open the rinsing pump. Send the rinsing pump to OASE. You will be sent an immediate replacement. ► Safety fuse ►...
  • Page 44: Technical Data

    Downloaded from www.watergardeningdirect.com - EN - Technical data ProfiClear Premium Compact-L EGC Pump fed system Gravity fed system Control device Rated voltage V AC Mains frequency Power consumption in idle state Power consumption during 1050 1050 cleaning cycle Rinsing pump output voltage...
  • Page 45 Downloaded from www.watergardeningdirect.com Staubgeschützt. Schmelzsicherung Mögliche Gefahren für Vor direkter Bei Frost das Gerät Nicht in Einlauf oder Auslauf Achtung! Nicht mit normalem Geschützt gegen 8 A / 250 V, träge Personen mit Herzschritt- Sonneneinstrahlung deinstallieren! greifen. Verletzungsgefahr Lesen Sie die Hausmüll entsorgen! Spritzwasser machern!
  • Page 46 Downloaded from www.watergardeningdirect.com...