3.4

Unit configuration

 E
Pump fed
 F
Gravity fed
1
1
2
2
3
3
4
4
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
16
17
18
19
20
20
21
21
22
22
23
23
24
24
25
25
26
27
27
28
28
29
29
30
30
31
31
32
32
33
33
34
34
35
35
36
36
Description
Container cover
Signal box with level detection device (3) and temperature probe (7)
• The signal box is connected to the control system (30, 32)
Level detection device
• Signals the water level in the filter system
Rollers for guiding the filter drum
Pump status detection
• Signals a pump failure
Filter drum with 8 screen elements
• Screen elements for coarse dirt down to 60 µm in size, optionally available
for 30 + 150 µm
Temperature probe
• monitors the water temperature
Air hose 9 mm
Hel-X 13 biomedia in Moving Bed filter chamber
2 × outlet DN 110
Aerator rod
Meshed tube
• Prevents theHel-X biomedia from being flushed out
Rinsing pump for supplying the rinsing device (24)
1 x dirt outlet DN 75 with slide valve
2 × adapters, 2 × 30° inlet bend with union nut for connection of the UVC
clarifier Bitron to 38 mm (1½ ") connections (18)
Connection set for filter pumps
• 1 × 50 mm (2 ") hose connector, 1 × union nut for hose connector, 1 × 40
... 60 mm hose clip, 1 × flat seal (2 ") 56 mm × 43 mm × 3 mm
1 × inlet 50 mm (2 ")
• For connecting a filter pump
2 × 38 mm (1½ ") inlet, closed with sealing plugs
• For connecting an optional UVC clarifier Bitron
3 × inlet DN 110 with cover cap
1 × optional inlet DN 110
• Must be cut out, if required (connection not included in the scope of
delivery)
1 × coarse dirt outlet DN 110
Drum motor for filter drum
• the motor is connected to the control system (30, 31)
Dirt channel
• Collects the coarse dirt and rinsing water from the screen elements (6)
Rinsing device
• Sprays water at high pressure onto the screen elements (6) to rinse off the
coarse dirt
Grease for the drum seal
2 × ground stakes for installing the control system
9/4 mm transition piece
Y piece
2 × cable binders for fastening the air hoses to the Y piece
Control system with EGC box
• Allows integration with cables into an EGC network.
Connector for drum motor
Connector for signal box
Mains connection cable
Connector for rinsing pump
Fuse holder
• Fuse protection of the control system with 5 × 20 mm, T8 A 250 V safety
fuse
2 × caps, cap nuts for fixing the EGC box
• Required for mounting the EGC box on the container wall