Page 2
Wassereinlauf Vorklärung Vortexsystem Filterschäume Wasserauslass Reinigungs-an- Funktions-schal- Reinigungshe- schluss Water inlet Clarifying Vortex system Foam filters Water outlet Cleaning con- Function switch Cleaning lever nection Entrée d'eau Préfiltration Système vortex Mousses fil- Sortie d'eau Raccordement Commutateur Levier de net- trantes de nettoyage de fonction toyage...
Information about these operating instructions Welcome to OASE Living Water. You made a good choice with the purchase of this product Filtoclear. Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit.
- GB - Correct electrical installation • Electrical installations must meet the national regulations and may only be carried out by a qualified electrician. • A person is regarded as a qualified electrician, if, due to his/her vocational education, knowledge and experience, he or she is capable of and authorised to judge and carry out the work commissioned to him/her.
Page 6
- GB - Installation Fitting hose connections The max. pump head height is 5m WC (0.5 bar). Only operate the unit with pressure hoses which are approved at least for 0.2 bar or the maximum pump pressure. Saw off the stepped hose nozzle at the appropriate point of the correspon- ding hoses (13).
- GB - Maintenance and cleaning Attention! Dangerous electrical voltage. Possible consequences: Death or severe injury. Protective measures: • Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the water.
- GB - Replacing the UVC lamp Change the UVC lamp after approx. 8,000 operating hours. Adhere to the safety information given above! Disconnect the power supply, switch off the pump and secure against unintentional switching on again. Undo the four screws of the UVC unit and carefully lift the unit out of the filter cover, unscrew the clamping screw by turning counter-clockwise, then remove the quartz glass tube including the O ring.