- EN -
System message
Motor blocked
Er44
(The control system
attempted to start up the
motor three times - 5 times
per attempt)
More than 960 cleaning
Er55
cycles in 48 hours
Switch element for rinsing
Er66
pump in the control system
overheated
The filter pump is not
Er88
supplying any water or
insufficient water.
70
Functions that are still
Possible cause
available
None
Filter drum rotating sluggishly or
jammed
The lips of the drum seal were
squeezed when the drum was installed.
The drum load is distributed unevenly
• Manual cleaning
Temporary heavy soiling
• Automatic mode
• Start-up phase of the filter system
(e.g. during the first start-up)
• Time-dependent cleaning
• Fish are spawning
Pond heavily soiled
Screen elements heavily soiled
Insufficient cleaning effect due to soiled
nozzle
Water level in the system too high:
• Outlet pipes soiled
• Outlet opening too small
• Max. flow rate exceeded
• A large amount of dirt has entered the
filter system, water is flowing over
(instead of through) the foam filters.
None
Control system is exposed to excessive
heat (sun, ambient temperature)
Pump status detection incorrectly set
• Manual cleaning
• Automatic mode
The filter pump is switched off.
• Time-dependent cleaning
The impeller unit of the filter pump is
blocked.
Remedy
• Clean edge of the drum/drum seal and grease edge of the
drum Only use original OASE grease (order number
27872).
• Ensure that the rollers move smoothly
• Remove larger particles (e.g. snails, stones) from the
sprocket
Disassemble the drum and ensure that the drum seal is
positioned correctly during re-assembly
Align the container horizontally
Wait until the soiling decreases
• This operating status is atypical. Avoid long-term operation
in this state.
• Clean the pond
• Reduce the amount of soiling
• Install the filter pump in an elevated position.
Clean the screen elements, descale (→ Replacing screen
element)
• Clean nozzle
• Clean outlet pipes
• Enlarge outlet opening
• Reduce flow rate
• Clean foam filters
Protect the control system from heat
Set the pump status detection. (→ E7: Pump status detection) Automatic after elimination of
Switch on the filter pump.
Clean the filter pump.
Resetting the system
message
Press
key for 5 s
• Press
key for 5 s
• Automatic if the number of
cleaning procedures drops
below 960.
Automatic when cooled down
the cause