7. Do not install, operate or store the device in a room smaller than
7m² ((Polar 70) / 9m² (Polar 90).
8. R290 is odourless, which means that you cannot smell leaks!
9. Persons working on the cooling circuit must be in possession of the
correct qualifications that state the person in question is competent
to use coolant in accordance with a special evaluation that is
recognised by the sector association.
10. The repairs must be executed on the grounds of the
recommendations of the manufacturer of the device. Maintenance
and repairs that require the assistance of other qualified persons
must be executed under supervision of someone who is specialised
in the use of flammable coolant.
Maximum effect
The maximum surface area, which this air conditioner can cool,
depends on various conditions. Conditions that cause the air conditioner
to cool smaller spaces are, for example:
- Higher outdoor temperature
- Many and/or large windows
- Flat roof
- Many people in the room
- Many electrical appliances in the room
If these conditions are present to a lesser extent (i.e. lower heat loads),
the air conditioner can cool a larger surface area better than if more of
these conditions are present (i.e. higher heat loads).
Lower heat loads
Higher heat loads
1. Do not place the unit in the vicinity of a heat source or in direct
sunlight.
2. Close windows and doors and keep curtains or hatches closed during
the sunniest hours in the day
3. Keep filters clean
4. Modify temperature and ventilation settings once the area has
reached the required condition.
Polar 70
22 m²
60 m³
14 m²
40 m³
60
Polar 90
29 m²
80 m³
18 m²
50 m³