Fujitsu AMUG24LMAS Design & Technical Manual page 97

Air conditioner duct type
Hide thumbs Also See for AMUG24LMAS:
Table of Contents

Advertisement

¢ Description of display
LED display lamp
(1) POWER/MODE
(2) ERROR
(3) MONITOR
Switch
• For the test run start and stop.
SW1
Push
• For the pump down start and stop.
SET1-1
DIP
For selecting cooling or heating during test operation.
SET1-2
DIP
For switching SW1 operation.
SET1-3
DIP
(Prohibited)
SET1-4
DIP
(Prohibited)
• For selecting outdoor unit low noise operation function.
SET2-1
DIP
• To use this function, the Central remote controller (option)
SET2-2
DIP
(Prohibited)
SET2-3
DIP
(Prohibited)
SET2-4
DIP
(Prohibited)
SET3-1
DIP
(Prohibited)
SET3-2
DIP
(Prohibited)
SET3-3
DIP
(Prohibited)
SET3-4
DIP
(Prohibited)
Be sure to disconnect the power supply or turn off the breaker before changing the DIP switch
setting.
12-1. Setting methods
Green
Red
A
Red
B
Red
C
Red
D
Red
E
Red
F
Red
Function or operation method
is necessary.
Function or operation method
• Turns on when the power supply is ON (Including
when error occurs).
• Indicate the MODE by the number of flashes when
the installation function is active.
Flashes at high-speed when there is an error.
• Displays the location and contents of errors when
there is an error. (Refer to Chapter 13-2.
on page 97 for details.)
- 93 -
"Error code"
Factory setting
OFF
OFF
OFF (Do not change)
OFF (Do not change)
OFF
OFF (Do not change)
OFF (Do not change)
OFF (Do not change)
OFF (Do not change)
OFF (Do not change)
OFF (Do not change)
OFF (Do not change)
12. Function settings