10) Switching functions for external output terminal
Functions of the external output terminal can be switched. For details, refer to "External input and
output".
Function number
60
11) Control switching of external heaters
Sets the control method for external heater to be used.
For details, refer to "External heater output" in Chapter 6-4.
Function
Setting value
number
61
7-2. Function settings by using remote controller
Setting value
00
01—04
05
06
07—08
09
10
11
00
01
02
03
Auxiliary heater control by outdoor temperature 1
04
Auxiliary heater control by outdoor temperature 2
05
Auxiliary heater control by outdoor temperature 3
06
07
Auxiliary heat pump control by outdoor temperature 1
08
Auxiliary heat pump control by outdoor temperature 2
09
Auxiliary heat pump control by outdoor temperature 3
Setting description
Operation status
Cooling thermostat On
Heating operation
Operation/Stop
Cooling thermostat On
Error status
Indoor unit fan operation status
External heater
"Details of function"
Setting description
Auxiliary heater control 1
Auxiliary heater control 2
Heat pump prohibition control
Auxiliary heat pump control
- 57 -
Factory setting
on page 27.
Factory
setting
7. Function settings