Fujitsu AG*F09LAC Instruction Manual
Fujitsu AG*F09LAC Instruction Manual

Fujitsu AG*F09LAC Instruction Manual

Indoor unit
Hide thumbs Also See for AG*F09LAC:

Advertisement

1. FLOOR TYPE :
AGF09LAC
AGF12LAC
AGF14LAC
INDOOR UNIT
R410A
D1D_AG003E/03
2011.04.20

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu AG*F09LAC

  • Page 1 R410A INDOOR UNIT 1. FLOOR TYPE : AGF09LAC AGF12LAC AGF14LAC D1D_AG003E/03 2011.04.20...
  • Page 2 1. FEATURE MODEL : AGF09LAC AGF12LAC AGF14LAC AOV09/12LA AOV14LA FEATURES Energy Efficiency Classification A Europe Energy Efficiency Classification A achieved Up and down twin fan operation Up to every corner of the room especially around the feet is heated evenly by two-direction up and down discharge.
  • Page 3 ALL DC fan motor V-PAM control rotary compressor DC Fan motor Super quiet operation Air flow mode can be set in 4 steps and more detailed air flow setting is possible. Inner drying operation This model is equipped with an inner drying function. After the power is turned off, the dry operation starts inside the air conditioner.
  • Page 4 2. REMOTE CONTROLLER 2-1. WIRELESS REMOTE CONTROLLER FEATURES Four kinds of timer setup (ON / OFF / PROGRAM / SLEEP) are possible. Four kinds of timers. Easy operation. Built-in timers Select from four different timer programs (On/Off/Program/Sleep). Program timer The program timer operates the ON and OFF timer once within a 24 hour period. Sleep timer The sleep timer function automatically corrects the temperature thermostat setting according to the time setting to prevent excessive cooling and heating while sleeping.
  • Page 5: Specification

    FUNCTIONS SLEEP button MODE button 10°C HEAT button SET TEMP. button ( COIL DRY button Signal Transmitter TIMER MODE button TIMER SET ( ) button FAN CONTROL button ECONOMY button START/STOP button SET button SWING button RESET button TEST RUN button This button is used when installing the conditioner, and should not be used un- der normal conditions, as it will cause the...
  • Page 6: Specifications

    3. SPECIFICATIONS FLOOR TYPE Type INVERTER HEAT PUMP Model name AGF09LAC AGF12LAC AGF14LAC Power source 230V 50Hz Available voltage range 198 - 264V 50Hz Cooling European energy label Heating 2.60 3.50 4.20 Rated BTU/h 8,900 11,900 14,300 Cooling 0.9 - 3.5 0.9 - 4.0 0.9 - 5.0 Min-Max...
  • Page 7: Installation Place

    4. DIMENSIONS MODEL : AGF09LA, AGF12LA, AGF14LA (Unit : mm) Side view Front view INSTALLATION PLACE 10 cm or more 8 cm or more 8 cm or more 5 cm or more 15 cm or below from the floor - (01 - 06) -...
  • Page 8 5. WIRING DIAGRAMS MODEL : AGF09LA, AGF12LA, AGF14LA INDICATOR PCB ASSY CN203 CN202 BLACK WHITE WHITE FAN MOTOR YELLOW WHITE ( UPPER ) BLUE WHITE WHITE WHITE WHITE WHITE BLACK WHITE WHITE FAN MOTOR YELLOW ( LOWER ) BLUE GRAY BLUE GRAY PIPE THERMISTOR...
  • Page 9 6. CAPACITY TABLE 6-1. COOLING CAPACITY MODEL : AGF09LA Indoor temperature °CDB °CWB °CDB 1.99 1.88 0.25 2.21 1.89 0.25 2.29 2.05 0.26 2.44 2.06 0.26 2.51 2.23 0.26 2.67 2.22 0.26 2.82 2.36 0.27 2.27 2.15 0.41 2.53 2.16 0.42 2.61 2.35...
  • Page 10 6-2. HEATING CAPACITY MODEL : AGF09LA 10.0 Indoor temperature °CDB °CDB °CWB 2.36 0.64 2.31 0.65 2.25 0.66 2.19 0.68 2.14 0.69 2.60 0.67 2.54 0.69 2.48 0.70 2.41 0.72 2.35 0.73 2.94 0.71 2.87 0.72 2.80 0.74 2.73 0.75 2.66 0.77 3.43...
  • Page 11 7. FAN PERFORMANCE 7-1. AIR VELOCITY DISTRIBUTION MODEL : AGF09LA, AGF12LA, AGF14LA Unit: m/s TOP VIEW Note : FLOW CONTROL PANEL : Horiz. Fan speed : H i LOUVER :Center Operation : FAN Voltage : 230V Fan select : UPPER&LOWER : UPPER FAN : LOWER FAN LOWER...
  • Page 12 7-2. AIR FLOW MODEL : AGF09LA, AGF12LA COOLING Number of rotations Fan speed [r.p.m] Air flow (UPPER/LOWER) HIGH 1190/1000 1000/850 820/690 QUIET 660/560 HEATING Number of rotations Fan speed [r.p.m] Air flow (UPPER/LOWER) HIGH 1240/1040 1040/880 840/700 QUIET 660/560 - (01 - 11) -...
  • Page 13 MODEL : AGF14LA COOLING Number of rotations Fan speed [r.p.m] Air flow (UPPER/LOWER) HIGH 1330/1120 1100/930 890/750 QUIET 660/560 HEATING Number of rotations Fan speed [r.p.m] Air flow (UPPER/LOWER) HIGH 1330/1120 1100/930 860/730 QUIET 660/560 - (01 - 12) -...
  • Page 14 8. OPERATION NOISE 8-1. NOISE LEVEL CURVE MODEL : AGF09LA COOLING HEATING NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 High High NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 Quiet Quiet NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000...
  • Page 15 MODEL : AGF14LA COOLING HEATING NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 High NC-50 NC-50 High NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 Quiet Quiet NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000 4,000 8,000 Octave band center frequency,Hz Octave band center frequency,Hz - (01 - 14) -...
  • Page 16: Sound Level Check Point

    8-2. SOUND LEVEL CHECK POINT Microphone Microphone Air Flow ● ● Air Flow - (01 - 15) -...
  • Page 17: Electric Characteristics

    9. ELECTRIC CHARACTERISTICS Model Name AGF09LA AGF12LA AGF14LA Voltage Power Supply Frequency Max Operating Current Circuit breaker *1)Wiring Spec. Connection Cable 1.5 - 2.5 1.5 - 2.5 1.5 - 2.5 Limited wiring length *1) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005) - (01 - 16) -...
  • Page 18: Safety Devices

    10. SAFETY DEVICES Model Protection form AGF09LA AGF12LA AGF14LA 3.15A 250V Circuit protection Current fuse (PCB) 3A 250V Terminal protection Current fuse °C OFF Fan motor protection Thermal protection program °C ON - (01 - 17) -...
  • Page 19: Function Setting

    FUNCTION SETTING 1 -1. INDOOR UNIT (Setting by remote controller) • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit malfunction. •...
  • Page 20: Function Details

    FUNCTION DETAILS  Functions Floor Cooler room temperature correction  Heater room temperature correction  Embedding the indoor unit in a wail  4) Auto restart  Indoor room temperature sensor  switching function 6) Remote controller signal code  1) Cooler room temperature correction Depending on the installed environment, the room temperature sensor may require a correction.
  • Page 21 4) Auto restart Enable or disable automatic system restart after a power outage. (  ... Factory setting) Setting description Function number Setting value  * Auto restart is an emergency function such as for power failure etc. Do not start and stop the indoor unit by this function in normal operation. Be sure to operate by the control unit, or external input device.
  • Page 22 REMOTE CONTROLLER SIGNAL CODE SETTING  Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.) Press the START/STOP button until only the clock is displayed on the remote controller display.
  • Page 23: Optional Parts

    12. OPTIONAL PARTS Exterior Parts name Model No. Summary SU MO TU WE TH FR SA Unit control is performed by Wired remote 3 6 9 12 15 18 21 UTB-UD wired remote controller. controller Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by Apple-catechin...
  • Page 24 12-1. WIRED REMOTE CONTROLLER FEATURES Various timer setup (ON / OFF / WEEKLY) are possible. Equipped with weekly timer as standard function. (2 times Start / Stop per day for a week) When setting up a timer, operation mode and a temperature setup can be changed.
  • Page 25 FUNCTIONS START/STOP button Pressed to start and stop operation. Set temperature button Selects the setting temperature. Master control button Selects the operating mode(AUTO, HEAT, FAN, COOL, DRY). Fan control button Selects the fan speed (AUTO, QUIET, LOW, MED, HIGH). Economy button Turns the economy efficient mode on and off.
  • Page 26: External Connect Kit

    12-2. EXTERNAL CONNECT KIT This kit allows to operate the air conditioner, such as stopping and starting, using an external device, and output the operation status of the air conditioner. • Only operation and stop signals will be output. Use the remote control to check the operation mode, temperature, and airflow. Check the error information on the display area of the main unit.
  • Page 27 12-2-2. Operating output setting • You can display air conditioner ON / OFF operation by external output. Signal specification • No voltage contact. • Contact capacity : Max. DC24V 10mA to 1A or less OPERATION Indoor unit status STOP SHORT External output signal OPEN Installation example...
  • Page 28: Outdoor Unit

    R410A OUTDOOR UNIT 2. SINGLE TYPE : AO V09LAC AO V12LAC AO V14LAC D1D_AO006E/03 2009.03.04...
  • Page 29 1. SPECIFICATIONS Type INVERTER HEAT PUMP Model name V09LAC V12LAC V14LAC Power source 230V 50Hz Available voltage range 198 - 264V 50Hz Starting current Cooling 1,680 1,680 1,910 Airflow rate Heating 1,490 1,680 1,750 Type × Q'ty Propeller fan × 1 Propeller fan ×...
  • Page 30 2. DIMENSIONS MODEL : AO V09LA, AO V12LA (Unit : mm) MODEL : AO V14LA INSTALLATION PLACE 100 mm or more 600 mm or more 100 mm or more 250 mm or 200 mm or more more 50 mm or more - (02 - 02) -...
  • Page 31: Refrigerant Circuit

    3. REFRIGERANT CIRCUIT MODEL : AO V09LA, AO V12LA, AO V14LA Indoor unit 3-Way Heat exchanger valve Muffler 2-Way valve 4-Way valve Strainer Expansion valve Strainer Outdoor unit Heat exchanger Refrigerant direction Cooling Heating - (02 - 03) -...
  • Page 32: Wiring Diagrams

    4. WIRING DIAGRAMS MODEL : AO V09LA, AO V12LA, AO V14LA REACTOR AO V09, 12L AO V14L COMPRESSOR R ( R ) YELLOW YELLOW WHITE WHITE BLACK S ( S ) WHITE WHITE C ( T ) BLACK BLACK PIPE THERMISTOR BLACK BLACK CN71...
  • Page 33: Capacity Compensation Rate For Pipe Length And Height Difference

    5. CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFFERENCE MODEL : AO V09LA, AO V12LA Pipe length (m) COOLING 0.915 0.905 0.955 0.922 0.912 Indoor unit is upper 0.974 0.959 0.926 0.916 than outdoor unit. 0.992 0.978 0.963 0.930 0.920 Height difference H...
  • Page 34 MODEL : AO V14LA Pipe length (m) COOLING 0.950 0.946 0.976 0.958 0.954 Indoor unit is upper 0.984 0.980 0.962 0.958 than outdoor unit. 0.992 0.988 0.984 0.966 0.962 Height difference H 1.000 0.996 0.992 0.974 0.969 1.000 0.996 0.992 0.974 0.969 -7.5...
  • Page 35: Additional Charge Calculation

    6. ADDITIONAL CHARGE CALCULATION MODEL : AO V09LA, AO V12LA, AO V14LA MODEL V09LA V12LA V14LA R410A Refrigerant type R410A R410A 1,150 1,050 1,050 Refrigerant amount REFRIGERANT CHARGE Pipe length 20g/m Additional charge 0 (Chargeless) +100 - (02 - 07) -...
  • Page 36 7. AIR FLOW MODEL : AO V09LA, AO V12LA, AO V14LA COOLING V09LA V12LA V14LA MODEL Number of rotations r.p.m. r.p.m. r.p.m. 1680 1680 1910 Air flow 1124 HEATING V09LA V12LA V14LA MODEL Number of rotations r.p.m. r.p.m. r.p.m. 1490 1680 1750 Air flow...
  • Page 37 8. OPERATION NOISE 8-1. NOISE LEVEL CURVE COOLING MODEL : AO V09LA MODEL : AO V12LA NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000...
  • Page 38 COOLING MODEL : AO V14LA NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 1,000 2,000 4,000 8,000 Octave band center frequency,Hz HEATING MODEL : AO V14LA NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 1,000 2,000 4,000...
  • Page 39 8-2. SOUND LEVEL CHECK POINT - (02 - 11) -...
  • Page 40 9. ELECTRIC CHARACTERISTICS Model Name V09LA V12LA V14LA Voltage Power Supply Frequency Max Operating Current 10.0 10.0 13.5 Starting Current Main Fuse (Circuit breaker) Current *1) Wiring Spec. Power Cable 1.5 - 2.5 1.5 - 2.5 1.5 - 2.5 *2)Limited wiring length *1) Wiring Spec.
  • Page 41 10. SAFETY DEVICES Model Protection form V09LA V12LA V14LA 20A 250V 20A 250V 20A 250V Current fuse (NEAR THE TERMINAL) 5A 250V 5A 250V 5A 250V Circuit protection 15A 250V 15A 250V 15A 250V Current fuse (MAIN PRINTED CIRCUIT BOARD) 3.15A 250V 3.15A 250V 3.15A 250V...

This manual is also suitable for:

Ag*f14lacAg*f12lac

Table of Contents