Braking Concepts - Siemens SIMOTICS T-1FW6 Series Configuration Manual

Naturally cooled built-in torgue motors for sinamics s120
Hide thumbs Also See for SIMOTICS T-1FW6 Series:
Table of Contents

Advertisement

Motor components and options
4.1 Motor components
4.1.5

Braking concepts

Uncontrolled coast down of the drive as a result of malfunctions
Malfunctions on a rotating machine axes can lead to the drive coasting to a stop in an
uncontrolled manner.
• Take the appropriate measures to brake the drive with its maximum possible kinetic
The design of mechanical braking systems depends on the maximum kinetic energy, that is,
the maximum moment of inertia of the rotating mass and its maximum speed.
Possible malfunctions
Malfunctions can occur e.g. for:
● Power failure
● Encoder failure, encoder monitoring responds
● Higher-level control failure (e.g., NCU); bus failure
● Control Unit failure
● Drive fault
● Faults in the NC
Below are a number of options showing how rotating masses can be braked in the event of a
malfunction.
68
WARNING
energy in the event of a fault.
Naturally cooled 1FW6 built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE01-0BP3

Advertisement

Table of Contents
loading

Table of Contents