Huawei SUN2000-55KTL Series User Manual page 85

Three-phase grid-tied pv string inverter
Hide thumbs Also See for SUN2000-55KTL Series:
Table of Contents

Advertisement

SUN2000-(55KTL, 60KTL) Series
User Manual
No.
Parameter
Description
11
Soft start
Specifies the duration
time
for the power to
gradually increase
when the SUN2000
starts.
12
Current
When the IV curves of
error
PV strings are being
during
scanned, the current
scanning
change of PV strings
operating properly
should be monitored to
avoid inaccurate
scanning caused by
sunlight change. If the
current exceeds the
specified value, it is
determined that the
sunlight changes, and
the IV curves should
be scanned again.
13
Hibernate
The SUN2000
at night
monitors PV strings at
night. If Hibernate at
night is set to Enable,
the monitoring
function of the
SUN2000 will
hibernate at night,
reducing power
consumption.
14
MBUS
For SUN2000 models
communic
that support both
ation
RS485 and MBUS
(PLC) communication,
when RS485
communication is
used, you are advised
to set MBUS
communication to
Disable to reduce
power consumption.
Issue 06 (2020-01-03)
Unit
Default
Value
s
The default
value varies
depending
on the grid
code. The
displayed
value
prevails.
A
0.20
N/A
Disable
N/A
Enable
Copyright © Huawei Technologies Co., Ltd.
7 Man-Machine Interactions
Value Range
Remarks
[20, 1800]
N/A
[0.00, 2.00]
N/A
Disable
N/A
Enable
Disable
N/A
Enable
79

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents