DESCRIPTION
Alarms are set on a per Display Value basis. High/Low Alarm points can be set for any value and will be
displayed visually & made audible.
During the wizard or manual setup you have the option to set an Alarm MIN & Alarm MAX.
Wizard or manual alarm points.
Example of a Shaft Alarm set at
Min of 1000RPM & Max of 3000RPM
When the alarm point is reach i.e. over 3000RPM the
line will FLASH notifying you of the issue.
Press ALARM to enter the page showing all Alarms
(active and inactive) to reset the alarm.
July 2013
more quick guides @ www.farmscanag.com/jackal
Manual/User setup Alarm points via the
FRONT SCREEN SETUP
In the example above Line 1 is ^ over the alarm set
point. If it was below it would show 1 v. You have 3
options
=AUTO : As soon as the value moves back within the
Min & Max range the monitor will automatically reset
the alarm.
=ON : When the alarm is activated it will remain ON
until you enter the ALARM menu and manually reset
=OFF : You can disable the alarm altogether
AM-Jackal-2