OUTPUT

FRONT SCREEN > SETUP > OUTPUT
Use the edit key to select the desired output option available on the desired port
Select the EDIT button to Disable or choose an output
function
In the above example the Jackal can be selected to
leave the output disconnected or pull low when an
alarm on a selected input is active. This can be used to
provide remote alarm functionality.
AM-Jackal-2
more quick guides @ www.farmscanag.com/jackal
When FREQUENCY is selected the Jackal will output a
pulse frequency that can be adjusted in ratio to a
selected input
i.e. in the above example, if a GPS was inputting serial
NMEA messages that contained speed information, the
output could be configured to pulse at a rate of 100
pulses / meter, therefore simulating a Radar.
Please refer to CONNECTION details on Page 3 for
connecting requirements
For Batching or Trip functionality the Jackal can be
used to turn ON or turn OFF a valve / warning or any
control function when a batch total or trip total has
been reached. Select your INPUT and the UNITS to be
measured.
Output