Summary of Contents for Cosel PAA50F
Page 1
Single Double Series Parallel protection Material [kHz] operation operation sided sided PAA50F Forward converter one converter 90 - 250 250V 2A Combination of inverter CEM-3 PAA75F Forward converter one converter 90 - 250 250V 3A Combination of inverter CEM-3...
Page 2
AC-DC Power Supplies Enclosed type Instruction Manual Terminal Block PAA-16 Function PAA-17 PAA-17 Input voltage range PAA-17 Inrush current limiting PAA-17 Overcurrent protection PAA-17 Overvoltage protection PAA-17 Output voltage adjustment range PAA-17 Remote ON/OFF PAA-18 Remote sensing PAA-19 Isolation PAA-19 Thermal protection Series Operation and Parallel Operation PAA-19...
Instruction Manual AC-DC Power Supplies Enclosed type l PAA150F 1 Terminal Block l PAA50F +Output Output voltage adjustable potentiometer -Output +Remote sensing(+S) Frame ground -Remote sensing(-S) +Output Output voltage adjustable potentiometer AC(L) Connector for Remote ON/OFF(Optional) -Output Connector for Remote ON/OFF(Optional)
Page 4
RC and RG terminals. 105% of the rated current. Overcurrent protection prevents the unit from short circuit and overcurrent condition of less than 20 PAA50F PAA75F PAA100F PAA150F sec. The unit automatically recovers when the fault condition is (Optional -R”) ”...
Ri = The internal resistance(see table) Model Ri [ ] (2)When using remote sensing function PAA50F/75F PAA100F/150F A wrong connection may damage the internal components of the unit. Remote ON/OFF circuit (RC(+), RC(-)) is isolated from input, out- put and FG.
Instruction Manual AC-DC Power Supplies Enclosed type PAA300F 2.9 Thermal protection lPAA300F PAA600F (1)When not using remote sensing function n Thermal protection is built-in. If this function comes into effect, shut down the output, eliminate all possible causes of overheating, and drop the temperature to normal level.
4.1 Installation method In parallel operation, the maximum operative number of units is 5. PAA50F PAA75F PAA100F PAA150F Output voltage in parallel operation is adjustable by using the po- When two or more power supplies are used side by side, position tentiometer of the ”master”...
Page 8
Instruction Manual AC-DC Power Supplies Enclosed type PAA50F PAA100F (1)Mounting method (1)Mounting method (2)Derating curve (2)Derating curve Specifications inside the hatched area, Ripple Ripple Noise is changed. PAA150F (1)Mounting method Note: In the hatched area, the specification of Ripple, Ripple Noise is different from other area.
PAA600F Derating curve Specifications inside the hatched area, Ripple Ripple Noise is changed. 4.3 Mounting screw Keep isolation distance between screw and internal components, as below chart. Unit : [mm] Model Model PAA50F PAA150F PAA75F PAA300F PAA100F PAA600F PAA-22 June 29, 2011...
Need help?
Do you have a question about the PAA50F and is the answer not in the manual?