  • Page 1: Table Of Contents

    Instruction Manual Unit type Terminal Blocks A-34 Functions A-35 Input Voltage Range A-35 Inrush Current Limiting A-35 Overcurrent Protection A-35 Overvoltage Protection A-35 Thermal Protection A-36 Output Voltage Adjustment A-36 Remote ON/OFF A-36 Remote Sensing A-37 Alarms A-38 Peak Current A-38 Series/Parallel Operation A-38...
  • Page 2: Terminal Blocks

    1AC (L) Input Terminals AC85 - 264V f47 - 63Hz 1 Terminal Blocks 2AC (N) (M4) 4Frame ground (M4 5-Output *The following information covers PBA300F - 1500F. Please see External 6+Output View for PBA10F - 150F and PBW15F - 50F. 7LED ¿ PBA300F...
  • Page 3: Functions

    2.1 Input Voltage Range ¿ PBA300F, PBA600F, PBA1000F and PBA1500F ¡ Input voltage range of the power supplies is from AC85V to ¡ Thyristor technique is used in the inrush current limiting circuit.
  • Page 4: Thermal Protection

    5.5V by serially connecting 1.73W to the TRM terminal as shown in Fig.2.2. 2.5 Thermal Protection +OUT +OUT ¿ PBA300F, PBA600F, PBA1000F and PBA1500F ¡ A thermal protection circuit is built-in. The thermal protection circuit may be activated under following conditions and shut down the output. You can also control...
  • Page 5: Remote Sensing

    ¡ These models have a built-in remote sensing function. In the case of PBA300F, the fan slows down when the output If you do not use the remote sensing function, you can short out voltage is turned off through the remote ON/OFF circuit.
  • Page 6: Alarms

    1 The time it takes until the PG signals turn ”High” vary depending 4.1 Series Operation on models and conditions. PBA300F and PBA600F ….. less than 1 second ¡ You can use a power supply in series operation. The output cur- PBA1000F and PBA1500F ….. less than 10 second...
  • Page 7: Parallel Operation/Master-Slave Operation

    � � � � � � [ rated current value ����������� ¿ PBA300F, PAB600F, PBA1000F and PBA1500F �� �� � ¡ You can use the power supplies in parallel operation by connect- � � � ��...
  • Page 8: Assembling And Installation

    ¡ Standard for Cooling ceed the temperature range shown in the derating curve. ¿ PBA10F, PBA15F, PBW15F, PBA30F, ¿ PBA300F, PAB600F, PBA1000F and PBA1500F PBW30F, PBA50F, PBW50F, PBA75F, PBA100F and PBA150F ¡ The power supplies have a built-in forced cooling fan. Do not block ventilation at the suction side (terminal block side) and its ¡...
  • Page 9: Expected Life And Warranty

    Instruction Manual Unit type ¿ PBA300F, PAB600F, PBA1000F and PBA1500F Annual Average of Ambient Load Factor 100% Temperatures All Mounting Ta = 40C or less 7 years* 7 years* Ta = 50C 6 years* 5 years Methods * Values with * are based on the assumption that fan maintenance will be properly done.
  • Page 10: Others

    Please avoid a Hi-Pot tester with a timer because, when the timer is turned ON or OFF, it may ¿ PBA300F, PBA600F, PBA1000F and PBA1500F generate a voltage a few times higher than the applied voltage.
  • Page 11: Options

    ¿ -F1 (PBA600F, PBA1000F, PBA1500F) Fig.7.3 Ambient temperature derating curve (-F3) -Option -F1 units have a longer-life fan instead of a standard fan. This option is not available for PBA300F. -Differences from standard versions are summarized in Fig.7.1 (Life expectancy of fan).
  • Page 12 Instruction Manual Unit type ¿ -F4 (PBA300F, PBA600F, PBA1000F and ¿ -J (PBA10F, PBA15F, PBW15F, PBA30F, PBA1500F) PBW30F, PBA50F, PBW50F, PBA75F, PBA100F and PBA150F) -Option -F4 units have a low-speed low-noise fan instead of a standard fan. - Option -J units have Molex connectors instead of a terminal -Differences from standard versions are summarized in Fig.7.4.
  • Page 13 Instruction Manual Unit type Inside of a Power Supply RC (+) Input Current External Power Source RC (-) Remote ON/OFF connector (Optional) Fig.7.7 Example of using a remote ON/OFF circuit - Dedicated harnesses are available for your purchase. Please see Optional Parts for details. *1 If the output of an external power supply is within the range Fig.7.8 Power supply installed on a DIN rail of 4.5 - 12.5V, you do not need a current limiting resistor R.