Pendulum control & isolation valve with devicenet interface, dn 160 mm i.d. 6" (94 pages)
Summary of Contents for VAT 75232-CE44 Series
Page 1
Wear gloves! lines. Do not touch parts under voltage! Read these «Installation, Operating & Maintenance Instructions» and the enclosed «General Safety Instructions» carefully before you start any other action! VAT Vakuumventile AG, CH-9469 Haag, Switzerland 207088EB 1/12 reception@vat.ch www.vatvalve.com Tel ++41 81 771 61 61 Fax ++41 81 771 48 30 Email...
Series 75.2, DN 40 (I.D. 1 ½”) Use of product Use product for clean and dry indoor vacuum applications under the conditions indicated in chapter «Technical data» only! Other applications are only allowed with the written permission of VAT. Technical data Leak rate <...
30 Nm / 22 lbf . ft Bending moment «M»: If a combination of both forces («FA» and «M») occurs, the values mentioned above are invalid. Please contact VAT for more information. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 207088EB 4/12 reception@vat.ch www.vatvalve.com...
To avoid malfunctions of the solenoid, we recommend to seal the thread of the compressed air inlet with liquid plastic (e.g. Loctite) and not by means of Teflon ribbon or similar fibrous material. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 207088EB 5/12 reception@vat.ch www.vatvalve.com...
Note: The controller has to be disconnected from the mains before it is disconnected from or connected to the valve. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 207088EB 6/12 reception@vat.ch www.vatvalve.com...
To open the valve, the cylinder is actuated by compressed air via a solenoid. The cylinder is engaged with the latch and pressurized again at the end of the opening movement. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 207088EB 7/12 reception@vat.ch www.vatvalve.com...
We recommend to use an emergency air reservoir at the compressed air input. Behavior in case of power failure The behaviour at power failure can be set inside the controller, either for «no change» or «valve closes». VAT Vakuumventile AG, CH-9469 Haag, Switzerland 207088EB 8/12 reception@vat.ch www.vatvalve.com...
Contamination from the process may influence the function and requires more frequent maintenance. Before carrying out any maintenance or repairs, please contact VAT. It has to be individually decided whether the maintenance/repair can be performed by the customer or has to be carried out by VAT. The fabrication number on the valve made in Switzerland Fabrication No.:...
2 or 3 steps, by means of the supplied hexagon pin spanner. Notice! A suitable torque wrench with the appropriate hexagonal insert to tighten the screws (torque: 9 Nm) is available from VAT (see Spare parts). 11. Connect socket (28/4) 12.