Commands Common to Both Digital and Analog Scales
In the following descriptions:
<lf>
represents an ASCII LF (0A hexadecimal)
<cr>
represents an ASCII CR (0D hexadecimal)
<enq>
represents an ASCII ENQ (05 hexadecimal)
<esc>
represents an ASCII ESC (1B hexadecimal)
Get Status
<lf>Xs<cr>
Command:
vvv.vv,iiiiiii,bbbbb
Response:
vvv.vv
is the voltage being provided to the NEST.
iiiiiii
is
Otherwise, it is seven spaces.
bbbbb
BOOST
is
About 225NEST
<lf>A<cr>
Command:
<lf>SMA:2/1.0<cr>
Response:
<lf>B<cr>
Command:
<lf>MFG:Cardinal Scale Mfg. Co.<cr>
Response:
<lf>B<cr>
Command:
<lf>MOD:225NEST<cr>
Response:
<lf>B<cr>
Command:
<lf>REV:x.x.xx<cr>
Response:
x.x.xx
(
represents the version of the 225NEST firmware)
<lf>B<cr>
Command:
<lf>END:<cr>
Response:
Get Information
<lf>I<cr>
Command:
<lf>SMA:2/1.0<cr>
Response:
<lf>N<cr>
Command:
<lf>TYP:<cr>
Response:
<lf>N<cr>
Command:
<lf>CAP:<cr>
Response:
<lf>N<cr>
Command:
<lf>CMD:INX<cr>
Response:
<lf>N<cr>
Command:
<lf>END:<cr>
Response:
SERIAL COMMANDS
ISO ERR
, if the isolated voltage regulator indicates an error condition.
, if the battery charger is in boost mode. Otherwise, it is five spaces.
4400-0020-0M Rev C  225NEST Operation
Reset Serial
<esc>
Command:
Response: none
Unrecognized Command
<lf>?<cr>
Response:
39