  • Page 2 THERMAL HEAT ALARM DEVICE Commercial reference: 3103-002 Developed by CAVIUS This Thermal Heat Alarm is designed for areas not suitable for smoke alarms due to high risk of false alarms such as; kitchens, garages or workshops. PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.
  • Page 3: Table Of Contents

    CONTENTS ........................1 Technical information ....................5 How to set up and connect alarms 2. The best areas to install the heat alarm ................................... 3. Areas where NOT to install the heat alarm ..........................4. Placement ......................5. Installing the heat alarm ..........................
  • Page 4: Technical Information

    32. one of the following batteries: DURACELL, PANASONIC or HUIDERUI. Please note: These must be alarms from the CAVIUS Interlinked by RF: 868 MHz. Complies to standards: EN54-5 class A1/R, EN300-220.
  • Page 5 MOUNTING BASE THERMISTOR RED LED TEST BUTTON...
  • Page 6: How To Set Up And Connect Alarms

    HOW TO SET UP AND CONNECT ALARMS: All alarms that need to be connected in the house should be put into ‘Learn Mode’ by sliding the switch on the back of the alarm to the ‘Learn Mode’ position. Start by pulling out the battery isolation DO NOT REMOVE THE strip as shown.
  • Page 7 Press the button at the top of one alarm only. This alarm will become The red LED will light up to indicate that ‘Learn Mode’ has been selected. the master and will start sending out a specific house code to the other alarms.
  • Page 8: The Best Areas To Install The Heat Alarm

    As the other alarms receive the specific house code, they will also flash the THE BEST AREAS TO INSTALL THE HEAT ALARM: LED light. • Areas not suitable for smoke alarms due to high risk of false alarms • Kitchen area •...
  • Page 9 AREAS WHERE NOT TO INSTALL HEAT ALARMS: • In rooms where the temperature goes outside -10ºC to +50ºC. • Bedrooms • Lounge • Dining room • Hallway • Family room NOTE: In areas where smoldering fires occur over flaming fires, photoelectric smoke alarms are still the best to be installed.
  • Page 10: Placement

    PLACEMENT: For celling installation: Ceiling Minimum 30cm The heat alarm is design to be installed on a ceiling or wall. Do not install to and maximum 50cm close to the oven/hob/stove (see drawing). from stove For wall installation: Ceiling Peak ceiling Ceiling Wall Minimum 50cm from wall...
  • Page 11: Installing The Heat Alarm

    INSTALLING THE HEAT ALARM: MARK UP Detach the alarm from the mounting base by twisting USE THE SCREW HOLES ENCLOSED counter clockwise. WITH A PEN SCREWS AND PLUGS Use the mounting base ring to mark the screw holes on the ceiling or the wall.
  • Page 12: Testfunction

    Once the mounting base is installed, attach the alarm by twisting clock- TEST FUNCTION: wise until it clicks. If the battery is either missing or inserted incorrectly, or After installation, and at least once per quarter, test all of your alarms to the switch is in ‘Learn Mode’, the heat alarm will not be able to click into ensure they are operating correctly and are within range of each other.
  • Page 13: Normal Mode

    2. Three short beeps every 8 seconds indicates a heat sensor fault. If required this indication can be stopped early on each alarm by a short press of the test button. If the problem continues, please visit www.cavius.com for any trouble shooting.
  • Page 14: Alarm Mode

    ALARM MODE: PAUSE/HUSH FUNCTION: When a rapid and constant change of temperature is detected, the heat alarm If the heat alarms are to set into a false alarm by cooking, fireplace, etc. they will go into ‘Alarm Mode’. It will sound the alarm signal and the LED will flash. can be paused for 10 minutes by pressing the test button on the originating heat alarm only (indicated by the flashing LED).
  • Page 15: Add Extra Device

    ADD EXTRA DEVICE: All CAVIUS interconnected alarms within the HEAT ALARM can be added to the system as they run on the same frequency and use the same data protocol.This means that the wireless system can consist of a combination of smoke, heat, flood etc.
  • Page 16: Low Battery Signal

    LOW BATTERY SIGNAL: BATTERY REPLACEMENT: Your product has a 5Y battery life. To replace the battery, detach the heat alarm from the mounting base by twist- When the battery is starting its end of life, a short beep will sound out every ing counterclockwise.
  • Page 17: Trouble Shooting

    Check if the battery is worn out and replace it. Always test the alarm after replacement of battery. Please note local regulations about information to your insurance company regarding installed heat alarms. If the problem continues, please visit www.cavius.com for any trouble shooting.
  • Page 18 D EV E L OP E D B Y: Tested to comply to the standard of system heat alarms EN54-5 class A1/R. Alarm condition aural signal pattern according to ISO 8201. CAVIUS Aps Julsøvej 16, DK-8600 Manufactured in P.R.C. 126770 rev1...