5
5 Year
50,000
Warranty
Hours
Important information
•
The luminaire and heat alarm must be installed in accordance
with local wiring regulations if in doubt seek advice from a
qualified electrician.
•
Before installing or completing maintenance work on the
luminaire and heat alarm make sure the mains power
is switched off.
•
The luminaire and heat alarm is designed for indoor use only.
•
The luminaire is dimmable, a trailing-edge dimmer must be
used.
•
The light source of this luminaire is not replaceable; when the
light source reaches its end of life the whole luminaire must
be replaced.
•
The luminaire is fire rated 30/60/90 minutes under
EN1365- 2014 fire test.
•
The driver provided is the only driver that can be used with
this luminaire.
•
The heat alarm can only be installed within the Lumi-Plugin
luminaire and not as a single unit.
Downlight specification
Brand:
Available Colours:
IP Rating:
Material:
Input Voltage to luminaire
Input Voltage to Driver
Power Output:
Colour Temp:
Light Colour:
Dimmable:
Fire Rating:
Luminaires per pack:
Product Diameter:
Product Depth:
Hours:
Lumens:
Beam Angle:
Dimmable
Beam Angle
is 60°
Lumi-Plugin
White or Chrome
IP65
Mixed (Metal and Plastic)
16V
220V - 240V 50/60Hz
9.5W
4000K or 2700K
Cool White or Warm White
Yes
30/60/90
1
120mm
70mm
50,000
700L
60°
Installation and Specification Sheet
LP120 Main Powered Heat Alarm Downlight
700
Fire Rated
Lumens
30/60/90
•
The heat alarm is powered by mains power (110-230V AC),
with a CR2 lithium back-up battery.
•
The heat alarm can be RF interlinked with other alarms in the
CAVIUS Wireless Family.
•
The Maximum number of alarms that can be interlinked within
a house group is 32.
•
The distance between interlinked alarms depends on the house
layout and should always be tested after installation. It is not
advised to install alarms with a separation of more than 10m.
•
The best areas to install the heat alarms:
•
Areas not suitable for smoke alarms due to high risk of
false alarms
•
Kitchen area
•
Bathroom
•
Garage or workshop
•
Do not install the heat alarms:
•
In rooms where the temperature goes
outside -10
C to +50
o
•
Bedrooms
•
Lounge
•
Dining room
•
Hallway
•
Family room
Heat alarm specification
Brand:
Battery Type:
Operation AC/DC:
Range:
Power Consumption:
Interlink Frequency:
Sound:
LP120WH/WARM/MBR/HA - LP120WH/COOL/MBR/HA
16V
CE Mark
C.
o
Lumi-Plugin
Replaceable CR2
110V AC, 230V AC
Minimum 100m in open field
161mAh in non-alarm condition
868MHZ
Audible indicator min 85dB @ 3
meter in anechoic successive tones
Driver
Included