Download Print this page

Cavius LUMI-PLUGIN LP120 Installation And Specification

Main powered heat alarm downlight

Advertisement

Quick Links

5
5 Year
50,000
Warranty
Hours
Important information
The luminaire and heat alarm must be installed in accordance
with local wiring regulations if in doubt seek advice from a
qualified electrician.
Before installing or completing maintenance work on the
luminaire and heat alarm make sure the mains power
is switched off.
The luminaire and heat alarm is designed for indoor use only.
The luminaire is dimmable, a trailing-edge dimmer must be
used.
The light source of this luminaire is not replaceable; when the
light source reaches its end of life the whole luminaire must
be replaced.
The luminaire is fire rated 30/60/90 minutes under
EN1365- 2014 fire test.
The driver provided is the only driver that can be used with
this luminaire.
The heat alarm can only be installed within the Lumi-Plugin
luminaire and not as a single unit.
Downlight specification
Brand:
Available Colours:
IP Rating:
Material:
Input Voltage to luminaire
Input Voltage to Driver
Power Output:
Colour Temp:
Light Colour:
Dimmable:
Fire Rating:
Luminaires per pack:
Product Diameter:
Product Depth:
Hours:
Lumens:
Beam Angle:
Dimmable
Beam Angle
is 60°
Lumi-Plugin
White or Chrome
IP65
Mixed (Metal and Plastic)
16V
220V - 240V 50/60Hz
9.5W
4000K or 2700K
Cool White or Warm White
Yes
30/60/90
1
120mm
70mm
50,000
700L
60°
Installation and Specification Sheet
LP120 Main Powered Heat Alarm Downlight
700
Fire Rated
Lumens
30/60/90
The heat alarm is powered by mains power (110-230V AC),
with a CR2 lithium back-up battery.
The heat alarm can be RF interlinked with other alarms in the
CAVIUS Wireless Family.
The Maximum number of alarms that can be interlinked within
a house group is 32.
The distance between interlinked alarms depends on the house
layout and should always be tested after installation. It is not
advised to install alarms with a separation of more than 10m.
The best areas to install the heat alarms:
Areas not suitable for smoke alarms due to high risk of
false alarms
Kitchen area
Bathroom
Garage or workshop
Do not install the heat alarms:
In rooms where the temperature goes
outside -10
C to +50
o
Bedrooms
Lounge
Dining room
Hallway
Family room
Heat alarm specification
Brand:
Battery Type:
Operation AC/DC:
Range:
Power Consumption:
Interlink Frequency:
Sound:
LP120WH/WARM/MBR/HA - LP120WH/COOL/MBR/HA
16V
CE Mark
C.
o
Lumi-Plugin
Replaceable CR2
110V AC, 230V AC
Minimum 100m in open field
161mAh in non-alarm condition
868MHZ
Audible indicator min 85dB @ 3
meter in anechoic successive tones
Driver
Included

Advertisement

loading

Summary of Contents for Cavius LUMI-PLUGIN LP120

  • Page 1 The heat alarm can be RF interlinked with other alarms in the • Before installing or completing maintenance work on the CAVIUS Wireless Family. luminaire and heat alarm make sure the mains power • The Maximum number of alarms that can be interlinked within is switched off.
  • Page 2 Installation instructions 1) Cut a circular hole in the ceiling (A) 92mm in diameter where 4) The heat alarm is held within the luminaire using magnets. The alarm comes with a cable fitted. Ensure the cable is the luminaire is going to be installed. Do not exceed the coming out of the back of the luminaire and connect to the cutting diameter.
  • Page 3 How to set up and connect alarms 1) Pull down the heat alarm away from the luminaire so the magnets are not connected anymore. (Diagram 5) 2) Twist the heat alarm anti clockwise to release the alarm from the mains power. 3) Pull out the battery isolation strip in the battery compartment as shown (Diagram 6) Please note: RF connection is done with the device...
  • Page 4 Please note: You can easily vacuum clean the heat chamber through the dedicated openings in the top cover, and it’s possible The CAVIUS Wireless Family have two different alarm signals: to test the alarms by pressing the cover at the same time.