TECHNICAL INFORMATION

Cavius heat alarm detects:
1) rapidly increased temperature level
2) absolute heat level of 58 degrees C.
The maximum number of alarms that can be interlinked within a house
group are 32.
Please note: These must be alarms from the CAVIUS
The distance between interlinked alarms depends on the house layout and
1
they should always be tested after installation. It is not advised to get more
than 10m distance between two alarms.
Diameter: 65mm. Height: 44mm.
The alarm is powered by a replaceable 3v CR123A lithium battery. Please
note that correct operation of the heat alarm device is ensured by use of
one of the following batteries: DURACELL, PANASONIC or HUIDERUI.
Interlinked by RF: 868 MHz.
Complies to standards: EN54-5 class A1/R, EN300-220.