  • Page 1 PLEASE READ THIS USER GUIDE CAREFULLY...
  • Page 3 Cavius DIY Smoke Alarm Model 2008-002 / 10012 / 10013 / 10014 Manufactured by CAVIUS PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE. For large text option and maintenance guide visit www.cavius.co.nz/resources www.cavius.com.au/resources...
  • Page 4 The CAVIUS™ is smoke alarm is a photoelectric alarm designed to be installed into residential homes, camper-vans and caravans. It is not recommended for boats. CERTIFIED TO AUSTRALIAN STANDARD AS3786:2014...
  • Page 5: Mounting Base

    MOUNTING BASE CHAMBER FILTER TEST/ HUSH BUTTON ALARM AUDIBLE ALERT...
  • Page 6 The best locations in your home to install the smoke alarm: Place a smoke alarm between possible fire • sources and bedrooms as a minimum. Smoke alarms on each floor, in hallways and • stairways. Smoke alarms in each room such as bedrooms •...
  • Page 7 MINIMUM INSTALLATION OPTIMUM INSTALLATION...
  • Page 8 Installation of smoke alarm: MARK UP SCREW HOLES Info: The label in the product WITH A PEN must not be removed due to important information regarding the product. 1. Use the mounting base ring to mark the screw holes on the ceiling. Use the enclosed screws and plugs for installing the mounting base.
  • Page 9 USE THE ENCLOSED SCREWS AND PLUGS FOR INSTALLATION CLICK THE SMOKE ALARM FIRMLY INTO THE BASE TO ACTIVATE...
  • Page 10 Placement: Designed for placement on ceiling (preferred) or wall. The smoke alarm should be a minimum 50 cm from the wall, with a minimum of one smoke alarm per floor and a maximum distance between smoke alarms of 10 metres. CEILING MINIMUM 50cm FROM WALL...
  • Page 11 2. After mounting, allow 5 seconds for the alarm to power up and then test the smoke alarm by pushing the test button (which is the entire top of the alarm). The alarm should produce a loud sound...
  • Page 12 The smoke alarm may NOT be placed: In dusty rooms • At the top of high pointed ceilings, instead place • a minimum of 50cm to a maximum of 150 cms from the appex. Within 50cm of a wall. • In rooms where the temperature goes outside •...
  • Page 13 Maintenance: The smoke alarm should be vacuum cleaned once per quarter, and can be wiped with a slightly damp cloth (do not open the alarm). Test the smoke alarm once per month by pushing the test button. The smoke alarm should produce a loud alarm tone.
  • Page 14: Functional Information

    FUNCTIONAL INFORMATION Type of alarm: CAVIUS™ smoke alarm is a photo electric smoke alarm. Alarm signal: Fire alarm activation is indicated by a series of repeated tones. The minimum sound level is 85 dB at 3 metres. Battery: Powered by...
  • Page 15 Low battery indicator: A short acoustic “beep” will sound and the LED will flash every 48 seconds when the battery is near the end of its life. In this stage it will continue for a minimum of 30 days. You must change the smoke alarm after 10 years of use, or if the smoke alarm has suffered any damage.
  • Page 16 Smoke alarm signal: The smoke alarms have a visual and acoustic signal. In the passive state, the LED will flash every 48 seconds to indicate normal function. In alarming state the LED will flash and the alarm will emit a sweeping sound pattern designed to alert occupants.
  • Page 17 Hush function: In case of unintentional or false alarms, press the hush button for 2 seconds (which is the entire bottom of the alarm). This will mute the alarm for 10 minutes, after which time the alarm will automatically resume its normal function.
  • Page 18 • Dust particles which have entered the smoke chamber, these can be removed by vacuuming around the mesh. If the smoke alarm does not work when the test button is pushed, please check our Trouble Shooting Guides at; www.cavius.co.nz and www.cavius.com.au...
  • Page 19 Other information: Do not paint the smoke alarm. • Note the local country regulations regarding • installation of mains powered smoke alarms in new buildings. Disposal: For battery and product, please dispose properly at end of life. This is electronic waste that should be recycled.
  • Page 20: Distributor Information

    Julsøvej 16 - DK8600 Silkeborg www.cavius.com - info@cavius.com Manufactured in P.R.C. DISTRIBUTOR INFORMATION: CAVIUS Nano Ltd. 8 King Street, Te Puke. 3119, Bay Of Plenty 3118. P.O Box 11241, Palm Beach Plaza, Papamoa, Bay Of Plenty 3151, New Zealand. www.cavius.co.nz Hotline: 0800 766533 or 07 542 2191 REP ELEC.
  • Page 21 This warranty is in lieu of any other warranty either expressed or implied. AS3786:2014 Model Number 2008-002 / 10012 / 10013 / 10014 126982 rev2...
  • Page 22 Product overview: Type of mounting Ceiling and Wall Mounting Main power supply Internal power source (battery included) Battery duration 10 years Interconnectable device Suitable for installation in mobile home...
  • Page 23 Connection to external auxiliary devices Radio link Individual alarm indicator Alarm silence facility (10min) No radioactivity infrared technology Accessibility option...