OPTICAL SMOKE ALARM DEVICE Commercial reference: 2103-002 Developed by CAVIUS The smoke alarm is designed for private homes, camping trailers, mobile homes and caravans. It is not recommended for boats. PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.
CONTENTS Technical information........................1 1. How to set up and connect alarms.....................5 2. The best areas to install the smoke alarm:................10 3. Areas where NOT to install the smoke alarm:................12 4. Placement: ..........................13 5. Installing the smoke alarm:.......................15 6. Test function:..........................18 7.
DURACELL, PANASONIC or HUIDERUI. group are 32. Interlinked by RF: 868 MHz Please note: These must be alarms from the CAVIUS Complies to standards: EN14604:2005 + AC:2008, EN300-220 The distance between interlinked alarms depends on the house layout and they should always be tested after installation.
Page 5
MOUNTING BASE CHAMBER FILTER TEST BUTTON RED LED...
HOW TO SET UP AND CONNECT ALARMS: All alarms that need to be connected in the house should be put into ‘Learn Mode’ by sliding the switch on the back of the alarm to the ‘Learn Mode’ position. Start by pulling out the battery isolation DO NOT strip as shown.
Page 7
Press the button at the top of one alarm only. This alarm will become The red LED will light up to indicate that ‘Learn Mode’ has been selected. the master and will start sending out a specific house code to the other alarms.
As the other alarms receive the specific house code, they will also flash the THE BEST AREAS TO INSTALL THE SMOKE ALARM: LED light. • Install an alarm between possible fire sources and bedrooms as a minimum. • Install alarms on each floor of the house, in hallways and stairways. •...
Page 9
AREAS WHERE NOT TO INSTALL SMOKE ALARMS: • In dusty rooms • At the top of a high pointed ceiling, in ceiling corners, and within 50cm of a wall. • In rooms where the temperature goes out side +4 to 38 C or above 90% relative humidity not condensing.
PLACEMENT: For catheral or peak ceiling or wall installation: The smoke alarm is design to be installed on a ceiling or wall. Ceiling Ceiling For ceiling installation: Wall The smoke alarm should be a minimum of 50cm from the wall. Minimum 30cm and maximum 50cm from Ceiling...
INSTALLING THE SMOKE ALARM: MARK UP Detach the alarm from the mounting base by twisting USE THE SCREW HOLES ENCLOSED counter clockwise. WITH A PEN SCREWS AND PLUGS Use the mounting base ring to mark the screw holes on the ceiling or the wall.
Once the mounting base is installed, attach the alarm by twisting clock- TEST FUNCTION: wise until it clicks. If the battery is either missing or inserted incorrectly, After installation, and at least once per quarter, test all of your alarms to or the switch is in ‘Learn Mode’, the smoke alarm will not be able to click ensure they are operating correctly and are within range of each other.
If required this indication can be stopped early on each alarm by a short press of the test button. TIP: It is safe to cover the sound output hole with your finger during the testing to minimize the sound level emitted. If the problem continues, please visit www.cavius.com for any trouble shooting.
ALARM MODE: PAUSE/HUSH FUNCTION: When a concentration of smoke is detected, the smoke alarm will go into If the smoke alarms are to set into a false alarm by cooking, fireplace, etc. they ‘Alarm Mode’. It will sound the alarm signal and the LED will flash. can be paused for 10 minutes by pressing the test button on the originating smoke alarm only (indicated by the flashing LED).
ADD EXTRA DEVICE: All CAVIUS interconnected alarms within the HEAT ALARM can be added to the system as they run on the same frequency and use the same data protocol.This means that the wireless system can consist of a combination of smoke, heat, flood etc.
LOW BATTERY SIGNAL: BATTERY REPLACEMENT: Your product has a 5Y battery life. To replace the battery, detach the smoke alarm from the mounting base by When the battery is starting its end of life, a short beep will sound out every twisting counterclockwise.
Check if the battery is worn out and replace it. Always test the alarm after replacement of battery. Please note local regulations about information to your insurance company regarding installed smoke alarms. If the problem continues, please visit www.cavius.com for any trouble shooting...
Page 18
D EV E L OP E D B Y: harmonized specifications of standard EN 14604 relating to Construction Products Regulation 305/2011. CAVIUS Aps Julsøvej 16, DK-8600 Manufactured in P.R.C. 0333 EN 14604:2005 + AC :2008 DoP no.: 2103-002 Download DoP document: www.cavius.com 126754 rev1...