Mounting And Beam Alignment; Mutual Interference Prevention; Distance From Reflective Surfaces - Omron F3SG-SR-K Series Quick Installation Manual

Safety light curtain
Table of Contents

Advertisement

Wiring

6. Mounting and Beam Alignment

6-1. Mutual Interference Prevention

When two or more F3SG-SR/PG systems are mounted in close proximity to each other, precautions should
be taken to avoid one system interfering with another, such as by beam alignment, back-to-back configura-
tion, physical barrier, Scan Code Selection, Operating Range Selection or adjusting the distances from adja-
cent safety light curtains.
In the Wired Synchronization, mutual interference is prevented in up to 3 sets, using interference light avoid-
ance algorithm.
In the Optical Synchronization, the scan code feature allows for placement of up to 2 sets of the F3SG-SR/
PG in close proximity and in line with each other. The distinctive coding of the beams provide for unique oper-
ation of a system while in view of another system with a different scan code. Two unique codes are available.
The emitter and receiver units must be set to the same scan code for the receiver to enter the MACHINE
RUN state. The scan code is selectable by the End Caps on the emitter and receiver units.
The F3SG-SR-K does not support the Scan Code Selection.

6-2. Distance from Reflective Surfaces

Install the sensor system at distance D or further from highly reflective surfaces such as metallic walls,
floors, ceilings, or workpieces, as shown below.
F3SG-SR (Type 4 ESPE)
Reflective ceiling
D
Emitter
Detection zone
L
D
Reflective floor
F3SG-SR (Type 2 ESPE)
Reflective ceiling
D
Emitter
Detection zone
L
D
Reflective floor
F3SG-SR-K
Quick Installation Manual
Mounting
Reflective surface
Emitter
Receiver
5
Distance between an emitter and a
receiver (operating range L)
0.3 to less than 3 m
3 m or more
Reflective surface
Emitter
Receiver
10
Distance between an emitter and a
receiver (operating range L)
0.3 to less than 3 m
3 m or more
Operation check
D
Receiver
5
L
Allowable installation distance D
0.13 m
L/2 x tan5 ° = L x 0.044 m
D
Receiver
10
L
Allowable installation distance D
0.26 m
L/2 x tan10 ° = L x 0.089 m
Step1
Check
position
Step2
Mount
5

Advertisement

Table of Contents
loading

Table of Contents