Low Level Debug Switch 2 - Eaton CMA User Manual

Table of Contents

Advertisement

Table 38 . 7 .2 .3 Low level debug switch 2
Input signal
processing debug2
4
CAN D Demand 1
5
CAN D Demand 2
8
CAN D Mode 1
9
CAN D Mode 2
10
Oil Compensated Temperature [C]
11
Temperature [C]
Algorithm debug 1
If mode 2 is: Single spool flow
1
State
3
Input Demand [lpm x 8]
4
Shaped Demand [lpm x 8]
If mode 2 is: Single spool float
1
State
If mode 2 is: Single spool pressure
1
State
If mode 1 is: Twin spool float
1
Combined state
4
WP2 State
If mode 1 is: Twin spool flow - IFC
1
state
3
Flow Demand [lpm x 8]
Raw 12-bit demand 1 from the internal CAN
Raw 12-bit demand 2 from the internal CAN
Raw Mode 1 from the internal CAN
Raw Mode 2 from the internal CAN
Temperature modified to adjust for viscosity of different oil types
Measured block temperature
1: Flow
2: Pressure Limit
3: Zero Flow Pressure Limit
Input flow demand
Flow demand after applying a flow shaper
1: Flow control
2: PWM open to tank
1: Pressure
2: Flow Limit
1: Either WP1 or WP2 is in Flow
2: Both WP1 and WP2 are PWM open to Tank
1: WP2 in Flow
2: WP2 PWM open to Tank
0: Zero Flow
10: Positive Flow - Passive
11: Positive Flow - Overrunning
12: Positive Flow - Pressure Limit
13: Positive Flow - Anti-fallback
20: Negative Flow - Passive
21: Negative Flow - Overrunning
22: Negative Flow - Pressure Limit
23: Negative Flow - Anti-fallback
Shaped flow demand
CMA USER MANUAL E-VLMB-TT005-E April 2019 www.eaton.com
CMA User Manual
41

Advertisement

Table of Contents
loading

Table of Contents