Pressure relief valve, pilot-operated
Table of Contents

Advertisement

Procedure after expiry
of the maximum storage
time of 12 months
Following disassembly
Store the valve in the original packaging or comparable packaging in order
to protect it from dust and dirt.
All connections at the valve must be closed with cap elements.
After opening the transport packaging, it must be closed properly again for
storage. Use the original packaging for storage.
1.
Check the complete valve for damage and corrosion prior to installation.
2.
In a test run, check the valve for correct function and leak-tightness.
After expiry of the maximum storage time, we recommend having the valve
checked by your competent Bosch Rexroth service. In case of questions regarding
spare parts, please contact the Bosch Rexroth service responsible for your valve,
see chapter 10.6 "Spare parts".
If a dismounted valve is to be stored, it has to be preserved for protection against
corrosion for the duration of storage.
Bosch Rexroth recommends the following procedure:
1.
Clean the valve; refer to chapter 10.1 "Cleaning and care".
2.
Close all connections so that they are airtight.
3.
Pack the valve with a desiccant air-tightly in corrosion protection film.
4.
Store the valve protected against shocks.
In each case, please observe any applicable provisions and laws regarding the
handling of substances hazardous to water or to health.
Transport and storage
RE25802-XC-B/07.19, DB...5X/...XC Bosch Rexroth AG
21/44