 Auxiliary heat pump control by outdoor temperature 1
• External heater output
Operation
Heater on
DIP-SW101-3
Indoor unit fan
setting for
external heater
Heater off
DIP-SW101-3
Indoor unit fan
setting for
external heater
– Temperature of heater on (Thon): Set temperature (Ts) - 0.9 °F (- 0.5 °C)
– Temperature of heater off: Set temperature (Ts) + 0.9 °F (+ 0.5 °C)
Tr-Ts ≥ 0.9°F
(0.5°C)
• Auxiliary heat pump On/Off
– Temperature of heater on (Thon): Adjustable by function number 62 (Operating temperature
switching of heat pump).
– All control temperatures will shift by adjusting "Thon".
Tr-Ts ≥ -1.8°F
(-1°C)
*: When room temperature stays in this zone for a specific time, auxiliary heater is turned on. For
details, refer to function number 71.
4-4. Details of function
Heater is on as shown in following diagram of heating temperature.
On
Heater is off as shown in following diagram of heating
temperature.
Other than heating mode
Error occurred
Enabled
Forced thermostat off
Fan stop protection
Off
Heater is off as shown in following diagram of heating
temperature.
Other than heating mode
Disable
d
Error occurred
Forced thermostat off
Tr-Ts
Off
Tr-Ts (=Thon) ≤ -0.9°F (-0.5°C)
On
Tr-Ts
Off
*
Tr-Ts (=Thon) < -5.4°F (-3°C)
On
- (05-46) -
Condition
Tr: Room temperature
Ts: Set temperature
Thon: Heater on temperature
Tr: Room temperature
Ts: Set temperature
Thon: Heater on temperature